Manual background
; wait for 34 processor cycles
Interfacing the TLV1562 Parallel ADC to the TMS320C54x DSP
; wait for 40 clock cycles [t(APDR)=1000ns]

Software Overview

port(DEACTIVE) = @ZERO

; deselect ADC (CS high)

NOP

; wait for tW(CSH)=50ns

* write CR0

 

 

 

port(ADC) = @CR0_SEND

; send CR0 value to the ADC

 

 

 

 

STEP1: port(DEACTIVE) = @ZERO

; deselect ADC (CS high)

NOP

;

 

 

*******************************************

*ADC_dual_IRQ_Start:

*read samples and store them into memory

*******************************************

ADC_dual_IRQ_Start:

ISTEP2: XF

= 0

; clear CSTART

ISTEP3: NOP

 

 

NOP

 

 

NOP

 

; wait for TW(CSTARTL)

.if (AUTO_PWDN_ENABLE)

* wait 800ns before finishing the sampling (requirment in Auto power down mode) repeat(#38)

nop

.endif

ISTEP4: XF

= 1

; set CSTART

STEP5:

.if POLLING_DRV

* wait until

INT– goes low in polling the INT0 pin:

 

= bit(*AR5,15–0)

 

 

 

 

 

 

M1: TC

; test, is the INT0 Bit in IFR=1?

 

 

 

 

 

if (NTC) goto M1

; wait until INT signal went high

 

 

 

 

IFR

= #1

; reset any old interrupt on pin INT0

.elseif INT0_DRIVEN

*user main program area (this could execute additional code)

*go into idle state until the INT0 wakes the processor up

USER_MAIN: IDLE(2)

; the user software could do something else here

goto USER_MAIN

;

.elseif NO_INT0_SIG

*instead of using the INT signal, the processor waits

*for 6ADCSYSCLK+49ns and reads then the sample

repeat(#32) nop

.endif

71

Image 77
Contents SLAA040 JulyApplication Report TParalInteMS3rflelADConvertertotheacing20C54xDSPtheTLV1562IMPORTANT NOTICE Contents 8.5.5 Figures List of FiguresList of Tables viSLAA040 1 Introduction Interfacing the TLV1562 Parallel ADC to the TMS320C54x DSP2 The Board 2.1 TMS320C54x Starter Kit2.3 ADC TLV1562 Overview 2.2 TLV1562EVM2.3.1 Suggestions for the ’C54x to TLV1562 Interface 2.3.1.1 The Universal InterfaceFigure 2. TLV1562 to ’C54x DSP Interface of the EVM Using RD or the CSTART Signal to Start Conversion2.3.2 Recyclic Architecture 2.4.1 TLC5618A - Serial DAC 2.3.3 Note on the Interface, Using an External ADC Clock Drive2.4 Onboard Components Figure 4. THS5651 to C542 DSP Interface 2.4.2 THS5651 - Parallel Output CommsDACFigure 3. TLC5618A to ’C542 DSP Interface 3.2 Input Data Bits 3 Operational Overview3.1 Reference Voltage Inputs 3.3 Connections Between the DSP and the EVM Table 1. Signal ConnectionsTable 2. 3-Position Jumpers 3.3.1 Jumpers Used on the TLV1562EVMTable 3. 2-Position Jumpers 8SLAA040Table 4. DSP/DAC Interconnection 4 The Serial DAC/DSP System5 The DSP Serial Port Table 5. DSP Serial Port Signals and Registers6.1 DSP Internal Serial Port Operation 6 Other DSP/TLV1562 Signals7 Conversation Between the TLV1562 and the DSP 7.2 Mono Interrupt Driven Mode Using RD7.1 Writing to the ADC Table 6. DSP Algorithm for Writing to the ADCtENDATAOUT = 41 ns Table 7. DSP Algorithm for Mono Interrupt Driven Mode Using RDtDCSL-sample+1ADCSYSCLK 14 SLAA040 7.3 Mono Interrupt Driven Mode Using CSTARTTable 8. DSP Algorithm for Mono Interrupt Driven Mode Using CSTART Table 9. DSP Algorithm for Dual Interrupt Driven Mode 7.4 Dual Interrupt Driven Mode16 SLAA040 7.5 Mono Continuous ModeTable 10. DSP Algorithm for Mono Continuous Mode Table 11. DSP Algorithm for Dual Continuous Mode 7.6 Dual Continuous Mode8.2 DSP Memory Map 8 Software Overview8.1 Software Development tools Figure 5. Memory Map 8.3 Programming Strategies for the ’C54x, Explanations 8.3.3 Timer Output8.3.1 Optimizing CPU Resources for Maximum Data Rates 8.3.2 Address and Data Bus for I/O Tasks8.3.6 Interfacing the Serial DAC 5618A to the DSP 8.3.5 Generating the Chip Select Signal and the CSTART Signal8.3.4 Data Page Pointer 8.3.8 Branch Optimization goto/dgoto, call/dcall 8.3.7 Interrupt LatencyGOTO MARK MARK DP = #1 ARP = #58.4.1 Software Principals of the Interface 8.3.9 Enabling Software Modules .if/.elseif/.endif8.4 Software Code Explanation 8.4.1.1 Software Polling 8.4.1.2 Timed SolutionAdvantage Disadvantage8.4.1.5 Setting the Right Switches 8.4.1.3 Interrupt Driven SolutionAdvantages DisadvantagesTable 13. Instruction in the Program Header Step Table 12. Switch SettingsTask 8.5.1 The Mono Interrupt Driven Mode Using RD to Start Conversion 8.5 Flow Charts and Comments for All Software ModesTable 14. Instruction in the Program Header Step 8.4.1.6 Common Software for all ModesOther Files Program FilesCode verification common file of all modes constants definitionFigure 6. Software Flow of the Mono Interrupt Driven Solution Calibration procedure of the DAC 8.5.2 Mono Interrupt Driven Mode Using CSTART to Start ConversionIncludes the complete software algorithm to control the monomode Common file of all modes constants definitionSAVE Initialize SPIPoll INTO Pin Until h/0 Transition Occurs Pull Down CSTARTThis only works for one TLV1562 not multiple because CS is not used 8.5.2.1 Throughput Optimization†Maximum Performance at 1.2 MSPS with Internal Clock 8.5.3 Dual Interrupt Driven ModeFigure 8. Time Optimization monocst1 IMPORTANT NOTE The code has been optimized to maximize the data throughput. It was found that CSTART can be pulled low earlier than the data read instruction is performed by the DSP. This saves the 100-ns wait time in STEP 3 because the data read requires at least 100 ns. Therefore, CSTART gets pulled high directly after data read, and the interface becomes faster and gains throughput. This variation will be found in the code. The data acquisition is done in a small number of steps that explains everything inside the code Interfacing the TLV1562 Parallel ADC to the TMS320C54x DSP 8.5.4 Mono Continuous Mode Figure 10. Flow Chart Mono Continuous Mode 8.5.5 Dual Continuous Mode Figure 11. Flow Chart Dual Continuous Mode Code verification 8.6.1.1 Constants.asm 8.6 Source Code8.6.1 Common Software for all Modes except C-Callable 42 SLAA040 set 000C0h Operate without calibrated inputs no offset8.6.1.2 Interrupt Vectors 44 SLAA040 4C internal timer interrupt8.6.1.4 Auto.bat 8.6.1.3 linker,cmdFile Linker.lnk COMMAND FILE title ”COMMAND FILE FOR TLV1562.ASM”pointer address when using any of the following variables Mainprogram Monomode.asmjump address to init. new channel counter for one channelsent value to register CR0 of the ADC 48 SLAA040 if SENDOUTSERIALendif if INT0DRIVENPOLLINGDRV endif endif if DIFFINPUTMODE if AUTOPWDNENABLE= bit*AR5,15-0 elseif INT0DRIVENelseif NOINT0SIG 52 SLAA040 CALIBRAT.ASM 8.6.3 Calibration of the ADC54 SLAA040 if SMECALIBRATION 56 SLAA040 endif 58 SLAA040 Interfacing the TLV1562 Parallel ADC to the TMS320C54x DSP 60 SLAA040 if INT0DRIVENPOLLINGDRV 62 SLAA040 = bit*AR5,15-0 64 SLAA040 endif if SAVEINTOMEMORYInterfacing the TLV1562 Parallel ADC to the TMS320C54x DSP Constants definition - see 8.6.1.1 Constants.asm 8.6.5 Dual Interrupt Driven ModeInterrupt Routine handler - see 8.6.1.2 Interrupt Vectors Mainprogram DUALIRQ1.asmInterfacing the TLV1562 Parallel ADC to the TMS320C54x DSP Software Overviewif SENDOUTSERIAL Software OverviewInterfacing the TLV1562 Parallel ADC to the TMS320C54x DSP 70 SLAA040 Software Overview 72 SLAA040 endif 74 SLAA040 8.6.6 Mono Continuous ModeMainprogram MONOCON1.asm Interfacing the TLV1562 Parallel ADC to the TMS320C54x DSP 76 SLAA040 endif if EXTERNALCLOCK 78 SLAA040 endif if SAVEINTOMEMORY 80 SLAA040 8.6.7 Dual Continuous ModeMainprogram DUALCON1.asm Interfacing the TLV1562 Parallel ADC to the TMS320C54x DSP 82 SLAA040 endif if EXTERNALCLOCK 84 SLAA040 Interfacing the TLV1562 Parallel ADC to the TMS320C54x DSP Mainprogram C1562.c 8.6.8 C-CallableTLV1562Channel, Save Memory Start address, NUMBEROFSAMPLES 80h samples of channel 1 will be stored beginning on 2000hInterfacing the TLV1562 Parallel ADC to the TMS320C54x DSP 88 SLAA040 AR7+ = data@ADSAMPLE 90 SLAA040 Vectors.asmint2 returnenable 48 external interrupt int2 nop 92 SLAA040 Auto.batLinker.cmd 10 References 9 Summary