Panasonic AJ-D850P manual Servo Control

Page 91

Counter display

Monitor display

Description

VTR operation

(Restart condition)

 

 

 

 

 

 

 

REEL DIR UNMATCH

REEL DIR UNMATCH

If the reel motor at the take-up side is running in the

STOP

 

 

reverse direction, the AUTO OFF lamp lights, and the

 

 

message display flashes.

(POWER OFFON)

 

 

 

 

 

 

 

REEL TENSION ERROR

REEL TENSION ERROR

If an abnormal tension at the supply side is detected

STOP

 

 

in the reel mode, the AUTO OFF lamp lights, and the

 

 

(POWER OFFON)

 

 

message display flashes.

 

SERVO COMM ERROR

SERVO COMM ERROR

When the servo microcomputer does not follow the

STOP

 

 

instructions of the system control microcomputer

 

 

even when 10 seconds have elapsed, the AUTO OFF

(POWER OFFON)

 

 

lamp lights, and the message display flashes.

 

 

 

 

 

SERVO CONTROL

SERVO CONTROL

When there is no response from the servo micro-

STOP

ERROR

ERR

computer for 1 or more seconds, the AUTO OFF

 

 

lamp lights, and the message display flashes.

(POWER OFFON)

 

 

 

 

 

 

 

SERVO ERROR

SERVO ERROR

When only the servo microcomputer was reset in an

STOP

 

 

instantaneous power failure, the AUTO OFF lamp

 

 

(POWER OFFON)

 

 

lights, and the message display flashes.

 

S-FF/REW TIMEOVER

S-FF/REW TIMEOVER

If the start/end processing operation is not completed,

STOP

 

 

the AUTO OFF lamp lights, and the message display

(POWER OFFON)

 

 

flashes.

 

S REEL ROTA TOO

S REEL TOO FAST

If the supply reel motor should rotate at an ab-

STOP

FAST

 

normally fast rate, the AUTO OFF lamp lights, and

(POWER OFFON)

 

 

the message display flashes.

 

S REEL TORQUE

S REEL TORQUE

If an abnormal torque applied to the supply reel motor

STOP

ERROR

ERR

is detected, the AUTO OFF lamp lights, and the

message display flashes.

(POWER OFFON)

 

 

 

 

 

 

 

 

 

T REEL ROTA TOO

T REEL TOO FAST

If the take-up reel motor should rotate at an ab-

STOP

FAST

 

normally fast rate, the AUTO OFF lamp lights, and

(POWER OFFON)

 

 

the message display flashes.

 

T REEL TORQUE

T REEL TORQUE

If an abnormal torque applied to the take-up reel

STOP

ERROR

ERR

motor is detected, the AUTO OFF lamp lights, and

(POWER OFFON)

 

 

the message display flashes.

 

UNLOAD ERROR

UNLOAD ERROR

If the tape has not been wound up during unloading,

STOP

 

 

the AUTO OFF lamp lights, and the message display

(POWER OFFON)

 

 

flashes.

 

WINDUP ERROR

WINDUP ERROR

If the tape was not wound up at less than the

 

 

 

standard speed (1) when the total tape amount was

STOP

 

 

not detected or if abnormal tape slack or tension was

 

 

detected at speeds above 1after the total tape

(POWER OFFON)

 

 

amount was detected, the AUTO OFF lamp lights,

 

 

 

and the message display flashes.

 

 

 

 

 

WINDUP REEL NOT

W-UP REEL NOT ROTA

If, after the cassette has been inserted, the tape take-

 

ROTA

 

up reel has not wound up the tape at the standard

STOP

 

 

speed (1) or faster while the total tape amount is not

(POWER OFFON)

 

 

detected and while the tape is traveling in the forward

 

 

 

or reverse direction, the AUTO OFF lamp lights, and

 

 

 

the message display flashes.

 

 

 

 

 

– 91 –

Image 91
Contents Operating Instructions Do not Open FCC NoteContents Features General and FeaturesMulti-function input/output interfaces Menu-driven setupRecording and playing back V blanking data Time codesFront panel Controls and their functionsFront Panel Top Section Channel condition lamps Input Select displayCassette insertion slot Eject buttonFront Panel Center Section @1TAPE/EE switch In the stop mode 8TC/CTL switch9TC/UB switch @0INT/EXT switch@4Search button @2REMOTE/LOCAL switch@6SHTL/SLOW switch @3REMOTE lamp#2IN a IN/SET/OUT a OUT buttons @9PREROLL button#0AUTO Edit button #1PREVIEW/REVIEW buttons#9Cassette insertion display lamp $5Headphones jack#7Time code buttons #8Warning lamp$7MONITOR Select switches $6Volume control$8METER FULL/FINE selector switch Front Panel Bottom Section 0DIAG button 7REC Inhibit switch8MENU button 9SET buttonConnector area CUE in connector AC in connectorSignal GND terminal Analog Audio in connectors9Remote control connectors 5ANALOG Component Video OUT connector6ANALOG Composite Video OUT connectors 7DIGITAL Audio IN/OUT connectorAnalog audio input connectors Reference input connectors Connections when one unit is usedInput connector Recorder Connections when 2 units are used deck to deckRemote control signal 9P Digital audio Analog video signal componentConnections with editing controller WFM VSC SwitcherPlayer Source machine Make these twoCassette TapesType Description ConsumerSwitching on the power/inserting the cassette Still Timer Setting STOP/STAND by modeRecording Selecting video/audio input signals2Adjusting the video level 3Adjusting the audio levelPlayback Shuttle mode Jog modeJog/shuttle Manual editing Preroll Automatic editing Deck to Deck Automatic editing Switch settings and adjustmentsWhen the unit is used as the recorder When the unit is used as the playerSelect the editing mode Match frame processing function Entering the edit pointsNegative duration function Calculating the duration Checking the edit points2Resetting either the edit in or OUT point 1Resetting both the edit in and OUT pointsModifying the edit points Preview Auto tag editing Executing automatic editingPostroll Retry functionReview Split editing Modifying the edit points Audio split editingEntering the edit points Deleting the edit pointsOperations Displaying the audio split edit pointsCueing up the tape to the edit points Duration displayVoice-over facility internal Operating procedureStop VTR For operation with an editing controller AG-A850Audio cross channel editing internal Example To record cross-faded audio signals onto CH2Connections Page Additional line recording/playback function Teletext signal recording/playback functionMode Additional lines Teletext signals Blanking data recording/playbackChroma level and hue Video output encoder output signal adjustmentsSetup level Video levelChanging the settings Setup default settingsSETUP-MENU Init SET YESPLAY/NOSTOP Changing the file Setup setting menusSetting and releasing the lock mode Setup menusUSER1 Loading a user fileSaving a user file Automatic loading of user file when the power is turned onDisplay Setting DescriptionSystem menu SystemSystem Setting Description Basic User menuBasic Setting Description Operation Memory stop function OperationRespns EE ModeFRZ Mode NormalInterface Edit Edit Setting Description JOG REV VAR REVJOG Step JOG FWDAmuvo AUD MEMMode AmuxTime Code Tape ProtectTC&UB DF ModeBlank TCGVaux video auxiliary data area Time CodeVideo SBC sub code data areaVideo Setting Description Audio Audio Setting Description CUE Slow DV PB ATTMoni SEL INHBlank Blank Setting Description Line 10&273 0000 Menu TCR 00 07 04 Frames Hours Seconds Minutes Time code/user bitTime code User bitTime code Setting the internal time codeSetting the external time code TC switch → EXT Recording internal/external time codesReproducing the time code/user bit Display position Operation modeSuperimpose screen Characters displayedServo reference What is the Servo REF on the setup menu No setting?Is the REF Video signal supplied? Is the input video signal available?During playback or special playback Servo reference setting tablesDuring recording or editing Audio V Fade Function CUE Printed circuit boardInner member Rack mountingCondensation Video head cleaningDiag menu Error messagesDisplaying the Diag menu Priority Monitor display Description VTR operation Displaying the Hours Meter informationItem No Description Priority Display DescriptionRestart condition Table of Auto OFF Error messagesPower OFF→ON Counter display Monitor display Description VTR operationServo Control Introduction Hardware specificationsExternal interface specifications RS-232C interfaceProtocol Software specificationsACK STX OPL ETX Error code tableWhen the communication has terminated abnormally Nack Return format VTR → controller PCCommands relating to operation control Notes Command tableStandby STX OBN ETX STX OSR ETXReverse Standby STX OBF ETXCommands relating to inquiries Notes CLS Microsoft QuickBASIC sample programPin No Signal Connector signalsPin No. Signal SignalPin No Abbreviation Circuit Description RS-232C Remote 25-pin D-SUB crossover cable supportedOther input/output connector SpecificationsParts Information & Ordering