Setup menus
OPERATION
| Item |
| Setting |
| |
|
|
|
| Description of settings | |
No. | Superimposed | No. | Superimposed | ||
| |||||
display | display |
| |||
|
|
| |||
|
|
|
|
| |
|
|
|
|
| |
161 | CTL BGN |
|
| For setting the BEGIN point in the repeat playback mode. | |
| or |
|
| Either TC or CTL is set as the counter display mode using the COUNTER button. | |
| TC BGN |
|
| If no mode is set, – | |
|
|
|
| BEGIN point. | |
|
|
|
|
| |
162 | END |
|
| For setting the END point in the repeat playback mode. | |
|
|
|
| Either TC or CTL is set as the counter display mode using the COUNTER button. | |
|
|
|
| If no mode is set, – | |
|
|
|
| point. | |
|
|
|
|
| |
163 | REPT MODE |
|
| For setting what images are to be output while the tape returns to the BEGIN point | |
|
|
|
| in the repeat playback mode. | |
|
| 0000 | FREEZE | 0: The tape returns to the BEGIN point with the image played back at the END | |
|
|
|
| point still frozen. | |
|
| 0001 | BLACK | 1: The tape returns to the BEGIN point while the screen remains black. | |
|
| 0002 | SW | 2: The tape returns to the BEGIN point following the setting selected by the | |
|
|
|
| TAPE/EE switch. | |
|
|
|
| <Note> | |
|
|
|
| If the tape end is set as the END point when “0:FREEZE” is selected, the playback | |
|
|
|
| image will not be frozen properly. | |
|
|
|
| Set the END point to a place within the range where images are recorded. | |
|
|
|
|
| |
180 | BATTERY SEL |
|
| For setting the type of battery. | |
|
| 0000 | NiCd12 | 0: 12 | |
|
| 0001 | NiCd13 | 1: 13 | |
|
| 0002 | NiCd14 | 2: 14 | |
|
| 0003 |
| 3: Setting for using the | |
|
| 0004 | 4: Setting for using the ENDURA80 | ||
|
| 0005 |
| 5: Setting for using the battery selected by the menu item No.181 | |
|
|
|
| item and No.182 | |
|
| 0006 |
| 6: Setting for using the battery selected by the menu item No.183 | |
|
|
|
| item and No.184 | |
|
|
|
|
| |
181 |
| 0000 | 10.6 | For setting (in increments of 0.1 V) the voltage level at which the counter flashes as | |
|
| : | : | warning for | |
|
| 0044 | 15.0 | item). | |
|
|
|
| <Note> | |
|
|
|
| When this item has been set to a voltage level close to 15.0 V, the counter display | |
|
|
|
| may flash even when an AC power source is being used. | |
|
|
|
|
| |
182 |
| 0000 | 10.6 | For setting (in increments of 0.1 V) the voltage level at which the | |
|
| : | : | (selected as the menu item No.180 [BATTERY SEL] item) is to be automatically | |
|
| 0034 | 14.0 | turned off. | |
|
|
|
|
| |
183 |
| 0000 | 10.6 | For setting (in increments of 0.1 V) the voltage level at which the counter flashes as | |
|
| : | : | warning for | |
|
| 0044 | 15.0 | item). | |
|
|
|
| <Note> | |
|
|
|
| When this item has been set to a voltage level close to 15.0 V, the counter display | |
|
|
|
| may flash even when an AC power source is being used. | |
|
|
|
|
| |
184 |
| 0000 | 10.6 | For setting (in increments of 0.1 V) the voltage level at which the | |
|
| : | : | (selected as the menu item No.180 [BATTERY SEL] item) is to be automatically | |
|
| 0034 | 14.0 | turned off. | |
|
|
|
|
|
“” indicates the factory setting.