Panasonic AJ-YA120AG manual Unload Error

Page 50

Error messages

Error No.

Error message and description

 

 

 

FRONT LOAD ERROR

 

This appears when the take-up reel turns without

E – 51

engaging the tape for the prescribed period of time

 

in the start end processing operation while the tape

 

is loading (at the half-loading position).

 

 

 

W-UP REEL NOT ROTA

 

This appears when the take-up reel has failed to

E – 52

take up the tape while the tape is running in the

 

status where the total tape duration is undetected

 

after the cassette was inserted.

 

 

 

WINDUP ERROR

 

This appears when the amount of tape taken up by

E – 53

the take-up reel and the amount supplied by the

supply reel while the tape is running are abnormally

 

 

different after the total tape duration has been

 

detected.

 

 

 

UNLOAD ERROR

E – 55

This appears when the tape has not been taken up

 

during unloading.

 

 

 

S-FF/REW TIMEOVER

E – 57

This appears when the tape start end processing

 

operation fails to be completed.

 

 

 

DRUM ROTA TOO SLOW

E – 59

This appears when the cylinder motor rotates

 

abnormally slowly.

 

 

 

DRUM ROTA TOO FAST

E – 60

This appears when the cylinder motor rotates

 

abnormally quickly.

 

 

 

CAP ROTA TOO SLOW

E – 61

This appears when the capstan motor rotates

 

abnormally slowly.

 

 

 

S REEL TOO FAST

E – 64

This appears when the supply reel motor rotates

 

abnormally quickly.

 

 

 

T REEL TOO FAST

E – 67

This appears when the take-up reel motor rotates

 

abnormally quickly.

 

 

Error No.

Error message and description

 

 

 

T REEL TORQUE ERR

E – 69

This appears when an abnormal level of torque has

been detected as having been applied to the take-up

 

 

reel motor.

 

 

 

This appears on the front panel’s counter display

 

when a communication error between the IF

E – 6A

microcomputer and front microcomputer has

 

occurred. At this time, the superimposed display will

 

be cleared.

 

 

 

S REEL TORQUE ERR

E – 70

This appears when an abnormal level of torque has

been detected as having been applied to the supply

 

 

reel motor.

 

 

 

CAP TENSION ERROR

E – 71

This appears when abnormal tension on the supply

 

side has been detected in the capstan mode.

 

 

 

REEL TENSION ERROR

E – 72

This appears when abnormal tension on the supply

 

side has been detected in the reel mode.

 

 

 

REEL DIR UNMATCH

E – 73

This appears when the direction of the take-up reel

 

motor has been reversed.

 

 

 

DRUM TORQUE ERROR

E – 74

This appears when an abnormal level of torque has

been detected as having been applied to the

 

 

cylinder motor.

 

 

 

M-IF COMM ERROR

E – 78

This appears when trouble has occurred in

communication between the mechanism relay board

 

 

and servo microcomputer.

 

 

 

BATTERY

E – bA

This appears when the input DC voltage has

dropped below the undercut voltage (approx.

 

 

10.6 V).

 

 

Consult your dealer if the error message display persists even after the unit has been restarted.

50

Image 50
Contents Operating Instructions Model No. AJ- EFor your safety Operating precautionFor U.K. only Contents Features IntroductionMulti-functional interfaces Parts and their functions Front panelSystem format lamp LOCAL/MENU/REMOTE switchRepeat lamp SCH lamp2@ Meter button and lamp CH34 Audio monitor selector switch? Analog lamp2 Audio output lamps CH12, CH34720p lamp Analog audio signal recording level controls2Volume control Headphone jackTAPE/EE switch REC button2 No optional board installedWhen the AJ-YA120AG or AJ-YAD120AG is installed Reset buttonDC in socket Rear panelAC in inlet DC OUT socketHD/SD REF Video in connectors and 75Ω termination switch2 TC in connector2TC OUT connector Audio in connectors CH1, CH2, CH3, CH42Inserting the tape Precautions for using consumer DV and Dvcam cassettesTapes Usable tapesOperation Turning on the unit’s powerStop mode Recording Pause/recording follow-on recordingStill image playback PlaybackCue/review Insert a cassette tape into the unit Press the Play buttonVariable speed playback When AJ-A95 is connectedLinear 0.3k playback Set the VTR to the menu mode Setting the Begin and END pointsSetting the repeat playback mode Repeat playbackTime code Setting the time codeTime code & user’s bit User’s bitPlaying back the time code and user’s bit Setting the user’s bitSelect menu item No.531 UB Preset T2R00 07 04Remaining tape display Superimposed screen displaysCharacters displayed Display positionSTA mode Operation modeTime mode M modeReturning to the factory settings Setup initial settingsSetting method using the on- screen menus Set the LOCAL/MENU/REMOTE switch to the Menu positionSetting the user defaults Loading the user defaults Menu protectionWith the hour meter displayed, press the Search button Releasing the menu protection modeDisplaying the Diag menu Setup menus Menus which are displayedTYPE-B Near Audio in SEL System Indicates the factory settingSetting Description of settings Superimposed Display HD SYS H ADV Setting Description of settingsSystem Freq Basic Format Display Manual SYS FormatPB Format AutoManual Dvcam HD-LP Formats for playback022 020 023 Playback format Operation Memory Mode FRZ Mode SELSP Mode INH Auto REWCTL BGN Rept ModeBattery SEL TC BGNInterface Tape ProtectTime Code TC Preset Phase CorrDF Mode UB PresetVideo BLK Clip ESR Mode SDCCR Mode SD CC F1 BlankAudio CH2 REC CUECH1 CH3Menu DIF in CH DIF ConfigDIF Speed DIF OUT CH23/24 Hz mode and 25 Hz mode Error messagesError No Error message and description Unload Error Condensation Operation performed by AJ-HD1200AProcedure to ejecting the tape manually in an emergency Video head cleaningMaintenance Emergency eject$ Video output connectors Specifications$ Video input connectors21 GeneralOther Connectors OptionsMemo Panasonic Broadcast Europe Panasonic Marketing Europe GmbH