Installation and connection

Figure: D

 

Recess

 

for cable

Adhesive surfaces between two grooves

Note before starting glueing work that the optimal processing temperature of materials to be glued and the sealing glue is between +15 °C und +25 °C. Prepare all necessary fastening elements and tools.

Prepare the tube of sealing glue in accordance with the instructions enclosed with the tube.

Remove the roof duct (Fig. A) and apply the sealing glue evenly to the underside of the roof duct flange.

Replace the roof duct in the drilled hole and press it firmly against the roof of the vehicle.

Apply the sealing glue evenly to the underside of the mounting plate, covering the whole area between the grooves (Fig. D).

This area must be completely glued onto the roof of the vehicle, in order to achieve the necessary adhesive force.

Place the mounting plate on the roof of the vehicle, as you have done already when marking the drilled holes.

Make sure that the arrow on the mounting plate points forward in the direction of travel.

The fastening holes must be perfectly aligned with the prepared holes in the roof.

Fasten the mounting plate in place with the prepared screws, making sure that all six screws are evenly tightened across the diagonals.

Note:

The sealing glue used is capable of bridging

small gaps

caused

 

by the curve of the vehicle’s roof. However,

you should

ensure

 

that the mounting plate is not bent by tightening the screws.

 

Remove any sealing glue that leaks out at the sides with a clean cloth or if necessary with Sikaflex® Remover (available from specialist dealers). Do not use a cleaning agent or thinner containing solvents, as this could damage the sealing glue applied under the mounting plate. Only wash your hands with washing paste and water.

Secure the cable duct by counter-tightening the knurled nuts supplied from inside the vehicle (Fig. A).

Note that the setting of the sealing glue depends on the ambient temperature and the humidity. Final strength is reached after approx. five days. However, it is possible to carry out further installation work with no problems, as the mounting plate is held in place by the tightened screws.

16

Image 16
Contents MobiSet 2 digital CAP Mobi Set 3 digital CAP Important information about MobiSet 2 digital CAP HTV 115 LCD/TFT television set is only included with the CAPForeign language installation instructions Components of MobiSet 3 digital CAP HDPUFD HTVProduct package Product packageInstallation instructions Proper useProper use Intended purposeSafety instructions important notes Safety during installation workProper installation and safety Fundamental informationSealing glue Road Traffic Licensing Regulations StVZOPower supply, fusing Checks before commencing a journeySafety precautions during installation Cleaning the antennaLowering the antenna while driving Safety instructions important notes Installation and connection Selecting the installation locationRequired tools and equipment Unpacking and preparationCables may not be cut, as otherwise the proper functioning Installation steps Installation of cable duct and mounting plateInstallation and connection Installation and connection Do not step on the connectors or kink the cables Installation of turntableVersion with cable duct below turntable Fig. E Version with external cable duct Fig. F Brief instructions for installing the HDP Tightening torque 6 NmInstallation of UFD Common interface modules should always be accessibleLaying cables and connecting the turntable HDP Connecting the UFD 170 to the on-board power networkImportant safety information for CAP Connecting the HTV 115 LCD TV SetFunction information for connection to on-board network Connection example motorhome 12 V battery connection UFD Connection example caravan 230 V battery connection UFD Safety notes BAS 60 planar antennaImportant information for use BAS 60 with HDPBAS 60 technical data Reception range/footprintPolarisation setting Polarisation settingInstallation process Motorhome/caravan On the turntableView after installation +15 Middle standardAddress of the service centre Electronic Service Chiemgau GmbH BahnhofstrasseDismantling for servicing DismantlingTechnical data Dimensions mmElectric data Sikaflex 291 data sheet Sikaflex 291 technical data sheet Declaration of conformity