Note: The Vex pin must not be connected when an external power source is connected on the expansion modules because the main SCO-100 unit will be damaged.

Image 16
Contents Page Disclaimer Contents Page Page Device overview ConnectionsLED indications Wiring Power supplyDigital inputs Digital outputs AC1Analog inputs Analog inputVin SCOM-100, User guide Analog input I/O expansion power supply SCOM-100, User guide GSM antenna MicrophoneGetting started Installing the SIM cardPreparing a SIM card First power up & factory settings SMS commands Device operationNaming the unit XXXX,A..A,..,..,Z..ZConfiguring a digital input for alarming 1100,m,n,s,a,d1100,0,1,Door contact,3,30 My SCOM-100 Door contact0630,ID,s Setting alarm message’s texts1101,m,n,ID1,ID2 0630,1,Door is opened 0630,2,Door is closed 0630,1,Door is opened 0630,2,Door is closed 1101,0,1,2,1My SCOM-100 Door contact Door is opened My SCOM-100Door contact Door is closed Clearing the digital input configuration1110,m,n Setting a digital output Controlling the digital outputs1000,m,n 1000,0,2Configuring an output as a closed contact 1001,0,21071,m,n 1071,0,21070,m,n Pulse digital output1010,m,n,s Setting a digital output after a delay1010,0,2,25 Resetting a digital output after a delay 1020,m,n,h,mn1021,m,n,h,mn Digital output time based scheduling 1040,m,n,mon,moffTime schedule program 1700,ID,d,P1B-P1D,P2B-P2D,…,P8B-P8D1030,m,n,ID 1700,1,0,800-120,1130-1001645-1801701,ID,P 1701,3,50 Clearing the digital output configuration1090,m,n,ID Analog input configuration Analog signal alarming1200,m,n,s,SSL,SSH,SCL,SCH,ALL,ALH,u,d ALH SCOM-100, User guide 1200,0,2,Pressure,819,4095,0,10000,2500 8500,mBar,15 Setting alarm message’s texts for analog inputs1201,m,n,ID1,ID2 Clearing the analog input configuration Setting the analog inputs alarm deadband1210,m,n 1800,d1 ON/OFF and PID control Special I/O Functions1250,id,m,n,m1,n1,sp,g,it,dt,ct,h 1255,id,sp 1251,id,s1253,id 1252,id,m,n1260,id Create a new user User administration0500,id,n,p,c1,c2,c3 Change user configuration Defining specific alarm recipientsSet a DI alarm recipient Delete a userClear DI alarm recipients Set an AI alarm recipientClear AI alarm recipients Device status & mode controls Setting the device statusRUN Control command Monitor commandControlling the device status Controlling the device response1105,m,n,v Send acknowledgement SMSMerge concurrent alarms Setting up an SMS counterResponse format Setting date and time Setting a GSM PINMonitoring commands Monitoring capabilities5100 UNITMy SCOM-100Connecting a PC Using the Hyperterminal for configurationSCOM-100, User guide SCOM-100, User guide Ate1 Using the Scom Configurator for configurationAtsms=1100,0,1,Door contact,3,30 Using the microphone input General parameter settings Command referenceAppendix SMS User configuration Output control & configuration Input configuration 5 I/O Functions RTC & Time scheduling Monitoring commands AI/DI/AO/DO Troubleshooting Page Technical specifications Main unitGE-DIO-42 Digital I/O Expansion module Error handling Status LED indications LEDDefault parameter values Factory settings GE-DIO-42 Digital I/O expansionSetting an I/O expansion module address Dip switch settings Module number m RS232C connector layout PIN