Contents
Page
Disclaimer
Contents
Page
Page
Device overview
Connections
LED indications
Wiring
Power supply
Digital inputs
Digital outputs
AC1
Analog inputs
Analog input
Vin
SCOM-100, User guide
Analog input
I/O expansion power supply
SCOM-100, User guide
GSM antenna
Microphone
Getting started
Installing the SIM card
Preparing a SIM card
First power up & factory settings
SMS commands
Device operation
Naming the unit
XXXX,A..A,..,..,Z..Z
Configuring a digital input for alarming
1100,m,n,s,a,d
1100,0,1,Door contact,3,30
My SCOM-100 Door contact
0630,ID,s
Setting alarm message’s texts
1101,m,n,ID1,ID2
0630,1,Door is opened 0630,2,Door is closed
0630,1,Door is opened 0630,2,Door is closed 1101,0,1,2,1
My SCOM-100 Door contact Door is opened
My SCOM-100
Door contact Door is closed
Clearing the digital input configuration
1110,m,n
Setting a digital output
Controlling the digital outputs
1000,m,n
1000,0,2
Configuring an output as a closed contact
1001,0,2
1071,m,n
1071,0,2
1070,m,n
Pulse digital output
1010,m,n,s
Setting a digital output after a delay
1010,0,2,25
Resetting a digital output after a delay
1020,m,n,h,mn
1021,m,n,h,mn
Digital output time based scheduling
1040,m,n,mon,moff
Time schedule program
1700,ID,d,P1B-P1D,P2B-P2D,…,P8B-P8D
1030,m,n,ID
1700,1,0,800-120,1130-1001645-180
1701,ID,P
1701,3,50
Clearing the digital output configuration
1090,m,n,ID
Analog input configuration
Analog signal alarming
1200,m,n,s,SSL,SSH,SCL,SCH,ALL,ALH,u,d
ALH
SCOM-100, User guide
1200,0,2,Pressure,819,4095,0,10000,2500 8500,mBar,15
Setting alarm message’s texts for analog inputs
1201,m,n,ID1,ID2
Clearing the analog input configuration
Setting the analog inputs alarm deadband
1210,m,n
1800,d
1 ON/OFF and PID control
Special I/O Functions
1250,id,m,n,m1,n1,sp,g,it,dt,ct,h
1255,id,sp
1251,id,s
1253,id
1252,id,m,n
1260,id
Create a new user
User administration
0500,id,n,p,c1,c2,c3
Change user configuration
Defining specific alarm recipients
Set a DI alarm recipient
Delete a user
Clear DI alarm recipients
Set an AI alarm recipient
Clear AI alarm recipients
Device status & mode controls
Setting the device status
RUN Control command
Monitor command
Controlling the device status
Controlling the device response
1105,m,n,v
Send acknowledgement SMS
Merge concurrent alarms
Setting up an SMS counter
Response format
Setting date and time
Setting a GSM PIN
Monitoring commands
Monitoring capabilities
5100
UNITMy SCOM-100
Connecting a PC
Using the Hyperterminal for configuration
SCOM-100, User guide
SCOM-100, User guide
Ate1
Using the Scom Configurator for configuration
Atsms=1100,0,1,Door contact,3,30
Using the microphone input
General parameter settings
Command reference
Appendix
SMS
User configuration
Output control & configuration
Input configuration
5 I/O Functions
RTC & Time scheduling
Monitoring commands
AI/DI/AO/DO
Troubleshooting
Page
Technical specifications
Main unit
GE-DIO-42 Digital I/O Expansion module
Error handling
Status LED indications
LED
Default parameter values Factory settings
GE-DIO-42 Digital I/O expansion
Setting an I/O expansion module address
Dip switch settings Module number m
RS232C connector layout
PIN