The command to reset an output after a delay is:

1021,m,n,h,mn

1021:

Command ID

m:

Module number (0 for SCOM-100 main

 

unit, 1-8 for DI-42 I/O expansion units)

n:

Output number (1-4 for SCOM-100

 

main unit, 1-2 for DI-42 I/O expansion

 

units)

h:

Delay off duration hours (0-21)

mn:

Delay off duration minutes (0-59)

Image 31
Contents Page Disclaimer Contents Page Page Connections Device overviewLED indications Power supply WiringDigital inputs AC1 Digital outputsAnalog input Analog inputsVin SCOM-100, User guide Analog input I/O expansion power supply SCOM-100, User guide Microphone GSM antennaGetting started Installing the SIM cardPreparing a SIM card First power up & factory settings XXXX,A..A,..,..,Z..Z SMS commandsDevice operation Naming the unit1100,m,n,s,a,d Configuring a digital input for alarmingMy SCOM-100 Door contact 1100,0,1,Door contact,3,300630,ID,s Setting alarm message’s texts1101,m,n,ID1,ID2 My SCOM-100 0630,1,Door is opened 0630,2,Door is closed0630,1,Door is opened 0630,2,Door is closed 1101,0,1,2,1 My SCOM-100 Door contact Door is openedDoor contact Door is closed Clearing the digital input configuration1110,m,n 1000,0,2 Setting a digital outputControlling the digital outputs 1000,m,n1071,0,2 Configuring an output as a closed contact1001,0,2 1071,m,nPulse digital output 1070,m,n1010,m,n,s Setting a digital output after a delay1010,0,2,25 1020,m,n,h,mn Resetting a digital output after a delay1021,m,n,h,mn 1040,m,n,mon,moff Digital output time based scheduling1700,ID,d,P1B-P1D,P2B-P2D,…,P8B-P8D Time schedule program1030,m,n,ID 1700,1,0,800-120,1130-1001645-1801701,ID,P 1701,3,50 Clearing the digital output configuration1090,m,n,ID Analog input configuration Analog signal alarming1200,m,n,s,SSL,SSH,SCL,SCH,ALL,ALH,u,d ALH SCOM-100, User guide 1200,0,2,Pressure,819,4095,0,10000,2500 8500,mBar,15 Setting alarm message’s texts for analog inputs1201,m,n,ID1,ID2 1800,d Clearing the analog input configurationSetting the analog inputs alarm deadband 1210,m,n1 ON/OFF and PID control Special I/O Functions1250,id,m,n,m1,n1,sp,g,it,dt,ct,h 1251,id,s 1255,id,sp1253,id 1252,id,m,n1260,id Create a new user User administration0500,id,n,p,c1,c2,c3 Delete a user Change user configurationDefining specific alarm recipients Set a DI alarm recipientClear DI alarm recipients Set an AI alarm recipientClear AI alarm recipients Monitor command Device status & mode controlsSetting the device status RUN Control commandSend acknowledgement SMS Controlling the device statusControlling the device response 1105,m,n,vMerge concurrent alarms Setting up an SMS counterResponse format Setting a GSM PIN Setting date and timeUNITMy SCOM-100 Monitoring commandsMonitoring capabilities 5100Using the Hyperterminal for configuration Connecting a PCSCOM-100, User guide SCOM-100, User guide Ate1 Using the Scom Configurator for configurationAtsms=1100,0,1,Door contact,3,30 Using the microphone input General parameter settings Command referenceAppendix SMS User configuration Output control & configuration Input configuration 5 I/O Functions RTC & Time scheduling Monitoring commands AI/DI/AO/DO Troubleshooting Page Main unit Technical specificationsGE-DIO-42 Digital I/O Expansion module Error handling LED Status LED indicationsGE-DIO-42 Digital I/O expansion Default parameter values Factory settingsSetting an I/O expansion module address Dip switch settings Module number m PIN RS232C connector layout