Infinite Peripherals SCOM-100 manual GE-DIO-42 Digital I/O expansion

Page 72

SCOM-100, User guide

72

9.5.2 GE-DIO-42 Digital I/O expansion

LED

Indication

 

 

POWER

Presence of power supply voltage

 

 

RST

Digital output reset during STOP or MONITOR

 

status

 

 

9.6 Default parameter values (Factory settings)

Parameter

Value

 

 

Device Name

SCOM-100

 

 

Device description

REMOTE CONTROL UNIT

 

 

Response format

Verbose

 

 

Send response SMS

Yes

 

 

SMS counting

Disabled

 

 

Merge concurrent alarms

Yes

 

 

GSM pin

None

 

 

Language

English

 

 

DI alarming

Disabled

 

 

AI alarming

Disabled

 

 

DO start up state

Open contact

 

 

User list

Empty

 

 

Time schedule list

Empty

 

 

Alarm message list

Empty

 

 

Image 72
Contents Page Disclaimer Contents Page Page Device overview ConnectionsLED indications Wiring Power supplyDigital inputs Digital outputs AC1Analog inputs Analog inputVin SCOM-100, User guide Analog input I/O expansion power supply SCOM-100, User guide GSM antenna MicrophoneInstalling the SIM card Getting startedPreparing a SIM card First power up & factory settings SMS commands Device operationNaming the unit XXXX,A..A,..,..,Z..ZConfiguring a digital input for alarming 1100,m,n,s,a,d1100,0,1,Door contact,3,30 My SCOM-100 Door contactSetting alarm message’s texts 0630,ID,s1101,m,n,ID1,ID2 0630,1,Door is opened 0630,2,Door is closed 0630,1,Door is opened 0630,2,Door is closed 1101,0,1,2,1My SCOM-100 Door contact Door is opened My SCOM-100Clearing the digital input configuration Door contact Door is closed1110,m,n Setting a digital output Controlling the digital outputs1000,m,n 1000,0,2Configuring an output as a closed contact 1001,0,21071,m,n 1071,0,21070,m,n Pulse digital outputSetting a digital output after a delay 1010,m,n,s1010,0,2,25 Resetting a digital output after a delay 1020,m,n,h,mn1021,m,n,h,mn Digital output time based scheduling 1040,m,n,mon,moffTime schedule program 1700,ID,d,P1B-P1D,P2B-P2D,…,P8B-P8D1700,1,0,800-120,1130-1001645-180 1030,m,n,ID1701,ID,P Clearing the digital output configuration 1701,3,501090,m,n,ID Analog signal alarming Analog input configuration1200,m,n,s,SSL,SSH,SCL,SCH,ALL,ALH,u,d ALH SCOM-100, User guide Setting alarm message’s texts for analog inputs 1200,0,2,Pressure,819,4095,0,10000,2500 8500,mBar,151201,m,n,ID1,ID2 Clearing the analog input configuration Setting the analog inputs alarm deadband1210,m,n 1800,dSpecial I/O Functions 1 ON/OFF and PID control1250,id,m,n,m1,n1,sp,g,it,dt,ct,h 1255,id,sp 1251,id,s1252,id,m,n 1253,id1260,id User administration Create a new user0500,id,n,p,c1,c2,c3 Change user configuration Defining specific alarm recipientsSet a DI alarm recipient Delete a userSet an AI alarm recipient Clear DI alarm recipientsClear AI alarm recipients Device status & mode controls Setting the device statusRUN Control command Monitor commandControlling the device status Controlling the device response1105,m,n,v Send acknowledgement SMSSetting up an SMS counter Merge concurrent alarmsResponse format Setting date and time Setting a GSM PINMonitoring commands Monitoring capabilities5100 UNITMy SCOM-100Connecting a PC Using the Hyperterminal for configurationSCOM-100, User guide SCOM-100, User guide Using the Scom Configurator for configuration Ate1Atsms=1100,0,1,Door contact,3,30 Using the microphone input Command reference General parameter settingsAppendix SMS User configuration Output control & configuration Input configuration 5 I/O Functions RTC & Time scheduling Monitoring commands AI/DI/AO/DO Troubleshooting Page Technical specifications Main unit GE-DIO-42 Digital I/O Expansion module Error handling Status LED indications LEDDefault parameter values Factory settings GE-DIO-42 Digital I/O expansionSetting an I/O expansion module address Dip switch settings Module number m RS232C connector layout PIN