| Table of Zones |
Zone # (led flashes) | Zone Name |
1 | Trunk |
2 | Shock Sensor |
3 | Door |
4 | Sensor 2 |
5 | Ignition |
6 | Hood |
Alarm Report when requested
The Alarm Report displays the two most recent alarm triggers depend- ing on the system state when requested. When disarmed, the report will display text to identify the two most recent triggers since the ve- hicle was last driven. When armed, the report will display text to identify the two most recent triggers since the system was armed.
Note The Alarm Report clears when ignition is turned on.
Nuisance Prevention (NPC)
NPC monitors all alarm zones and, if any are triggered excessively, bypasses them until corrected. If a point of entry (trunk, hood, door) is left open following a forced entry, it is bypassed. It becomes active again only after being closed.
Bypassed sensors automatically reset after one hour and after the vehicle is driven. Disarming then
Feature Details
© 2011 Directed Electronics. All rights reserved. | 33 |