![](/images/new-backgrounds/1164505/16450599x1.webp)
Events:
Message
Power Up
Remote Monitor Login/ logout
Local/Remote switch change
Soft Reset
Low Power and/or
Alarm Events
Loss of Signal; Signal Restored
Received Loop Up/
Received Loop Down
Code
Received Unframed 1’s; Stopped receiving Unframed 1’s
Loss of Framing; Fram- ing restored
received Yellow Alarm; Yellow Alarm not being received
Explanation
This is an informational message that logs the time and date that the stytem was powered up.
This is an informational message that logs the time and date that users logged into and off the Remote Monitor software.
This is an informational message that logs when the Local/ Remote switch on the Access Bank II was changed.
This is an informational message that indicates that the sys- tem has detected a soft reset
This is an alarm message logging information about condi- tions in which the power dips below standard levels. Note that when power is cycled off and then on again, the Access Bank II logs a brownout event. This is a normal part of operation, and you can ignore these messages.
The Loss of Signal alarm indicates that the Access Bank II has stopped receiving the T1 signal. The Signal Restored message indicates that the signal has been restored follow- ing a Loss of Signal alarm.
The Received Loop Up Code message indicates that the Access Bank II has received an
The Received Unframed 1s message indicates that the Access Bank II has received unframed ones, and the Stopped Receiving Unframed 1s message indicates that the system is no longer receiving unframed ones following a Received Unframed 1s message.
The Loss of Framing message indicates that the system received unframed data (all ones). The Framing Restored message indicates that Framing has been restored following a Loss of Framing error.
The Received Yellow Alarm message indicates that the sys- tem is receiving yellow alarms. The Yellow Alarm Not Being Received message indicates that the yellow alarm is no longer being received.