aPOWER switch
Set this to the ON position to power on this unit.
bCONTROL PANEL connector
Connect an optional
cCONTROL PANEL switch
This selects whether an optional control panel is connected to the connector on the front panel or to the connector on the rear panel. If there are control panels connected to both connectors, this switch determines which is enabled.
FRONT: Enables the control panel connected to the connector on the front panel.
REAR: Disables the control panel connected to the connector on the front panel.
dMEMORY CARD slot
Insert the memory card (sold separately) in this slot. Settings made on the Setup menu can be saved and read on a memory card as required.
To remove the card, press the eject button next to the slot.
Note
Do not eject the memory card while the ACCESS lamp is lit as this may damage the information on the memory card.
eSET UP SELECT switch
This selects the number of the menu bank for this unit’s settings. The menu bank selected by changing the switch setting becomes effective after the unit is restarted. However, changes are not effective if made while the power is off do not become effective the next time the power is turned on. In order to make the changes effective, either cycle the power off and on again, or reboot by means of the FAST REBOOT item (item number 027) in the basic menu. The currently valid menu bank is indicated by the MENU BANK indicators. You can change the settings of the current menu bank by pressing the MENU button to display the setup menu. To change the settings of any other bank, select the bank with the SET UP SELECT
switch while the setup menu is displayed.
For details of setup menus, see Section
fPANEL SELECT switch
This switch enables or disables each of the meter panels fitted as standard to this unit and the operation control panel. The switch settings are as follows. NONE: Both of the control panels are disabled. METER PANEL: The meter panel only is enabled. CONTROL PANEL: The control panel only is
enabled.
BOTH: Both of the control panels are enabled.
gCHARACTER switch
This switch selects whether or not timecodes and other character information is superimposed on the video signal output from the MONITOR OUTPUT connector.
ON: Superimposed information is output.
OFF: Superimposed information is not output. The factory default setting is ON.
*When the basic menu item ANALOG MONITOR SUPERIMPOSE (menu 008) is set to “inhibit”, superimposition cannot be enabled from the ANALOG COMPOSITE (SUPER) connector.