Sony MAV-555SS Basic Operations with DTR+Panel and DTR+DTR Modes, EE Signal Selection

Page 79

1 While holding the SHIFT key on the Control Panel, press B1 (Unload).

2 Turn the MULTI CONTROL knob to select the next material to play, and press B1 (Load).

Note

Depending on the settings for the Control Panel, Step 1 may not be necessary.

Please refer to the BKMA-505 Control Panel Operating Manual for details.

Note

Combinations of ports that can be used with EE operation are as indicated by the circles in the table below.

 

 

Playback port

 

 

 

 

 

 

 

P1

P2

P3

 

 

 

 

 

 

R1

O

O

O

 

 

 

 

 

Recording port

R2

O

O

 

 

 

 

 

 

 

R3

O

 

 

 

 

 

 

 

5-3-3 EE Signal Selection

In panel mode, when EE signal output has been specified for each playback port, it is possible to specify the recording port for which the EE value is to be output.

In order to make this specification, hold down the PORT SELECT button that corresponds to the target playback port, and then press the PORT SELECT button for the recording port for which the EE value is to be output.

While the PORT SELECT button for a recording port is pressed, that EE signal is output. When the PORT SELECT button for that recording port is released, the output returns to the PB picture.

Subsequently, if the EE picture output specification is made for this playback port, the input signal for the recording port that was specified by the initial operation is output as the EE picture.

(Operation Example)

Outputting the R2 port signal when the EE specification is made for the P1 port:

1 While holding down the P1 key, press the R2 key. While the R2 key is held down, the R2 input signal is output to P1.

2 Press the R2 key.

The display returns to the P1 PB picture. Subsequently, if the EE specification is made for the P1 port, the input signal for the R2 port is output as the P1 EE signal.

Note

In Expansion menu item REFERENCE SELECT (menus 349 to 351), when the recording port standard signal is set to “input video”, the EE picture is not output.

For details about the setup menu, refer to Section 3-4, “Setup” (page 3-18).

Chapter 5 Basic Functions of

5-4 Basic Operations with DTR+Panel and DTR+DTR Modes

Each Mode

In DTR+Panel mode, the R1 and P1 ports are controlled through the DTR-3000, while the other ports are controlled through the control panel or an external device. In DTR+DTR mode, R1/P1 and R2/P2 are each controlled separately through two DTR-3000s.

5-4-1 Initial Setup for DTR+Panel and DTR+DTR Modes

Before using the DTR+Panel and DTR+DTR modes, confirm and set up the following:

(1)The DTR-3000 version connected to this unit must be CP:V01.30, VS:V01.20 or later.

(2)The DTR-3000 must be set to the DISK:INDIVIDUAL mode.

(3)The DTR-3000 recording time should be set on this unit.

(4)Whether or not loop recording is used, it should be set on this unit.

(5)Whether or not partial save is performed should be set on this unit.

Please contact your supplier or Sony representative if you require more details about (1) and (2) above.

For more details on (3) and (4) above, please refer to the following operating information.

Setting the Recording Time from the DTR- 3000

1 Set DTR-1 (and DTR-2) in LIVE DURATION (menu 034) on the basic menu to the desired time.

5-4 Basic Operations with DTR+Panel and DTR+DTR Modes 5-3 (E)

Image 79
Contents MAV-555SSVer Avertissement Für Kunden in Europa For the customers in the USAFor the customers in Europe Pour les clients européensTable of Contents Organization of this manual Purpose and intended audience for this manualDescriptions of operating procedures Using this manualMaintenance Manual Option Installation Manual suppliedRelated manuals Page SS mode only FeaturesMAV-555SS Overview Common to SS and SD modes SD mode only Changes from Ver Optional AccessoriesChanges from Ver .00 to Ver Editing Fader Panel BKNE-1011 E 1-4 Optional Accessories Front Panel Names and Functions of PartsPort Select Meter PanelLED indicators Operating panel indicators Timer SEL time data display select buttonERROR/WARNING indicators System indicator HDD indicatorStatus indication Display indicators panelIndicators Time data indicationChroma Phase button PB/REC indicatorsVideo Process setting section Setup LEVEL/BLACK Level buttonBlank Panel System Setup PanelRemote button SET UP Select switch Power switchControl Panel connector Control Panel switchSDI OUT connectors Connector PanelAudio OUT AES/EBU connectors BNC type Video in Composite connectors BNC typeVideo OUT Composite connectors BNC type Audio in AES/EBU Digital Audio Input connectors BNC typeSdti CP connectors SDI Super connectorAnalog Composite Super connector DSK in connectorsAnalog Audio Expansion Box BKMA-570 Page Motion modes Two modes MAV-555SS ModesOperation modes Four modes SS Mode Sony Super Motion Mode Panel ModeVTR SD Mode Standard Motion modeSS Mode DTR + Panel ModeSD Mode MAV-555SS Modes 3-5 E DTR + DTR Mode SD mode only MAV-555SS BVE Mode SD mode onlyEditing Panel Monitor Ntsc BLOCK-1 10 E Connecting External DevicesConnections with the Panel Mode Connecting to digital devices SS modeOUT Connecting to digital devices SD modeAnalog Audio OUT Connecting to analog devices SD modeConnecting with the DTR+Panel mode SS mode Connections with the DTR + Panel Mode13 E Sync Generator Dynamic Motion Controller DTR-3000 Connecting with the DTR+Panel mode SD mode15 E Connections with the DTR + DTR ModeBVE Mode Connections External Synchronization of Output Video Signals How to Read the Tables SetupBasic Menu Settings 18 E 3-4 SetupCharacter H-POSITION Local Function EnableDrop Frame Mode with Preroll Time20 E 3-4 Setup DTR-1 Loop REC Port ConfigurationDTR CUE List Clear Live Duration22 E 3-4 Setup Basic Menu Operation To cancel setting changesModes of operating the Menu control Menus including a setting submenu 24 E 3-4 SetupMenu items with submenus Press the Menu knob Contents of the Expansion Menu Setup Bank Load Setup ALLSave Setup ALL Load Setup Bank28 E 3-4 Setup PIN 26 . Function ConfigurationGPI Output PIN 9 . Function30 E 3-4 Setup Preset Replace Audio Fade Mode P1Audio Fade Mode P2 Audio Fade Mode P332 E 3-4 Setup Function Mode After Cueup P3 SUB Menu Edit DelayEdit Preset Commend Function Mode After34 E 3-4 Setup F1 Select SettingNON Compress Line R1 NON Compress Line R236 E 3-4 Setup Blanking Width P1 Delay Monitor Video DelaySync Delay Internal Signal38 E 3-4 Setup Internal Audio Signal Audio Output Phase P1Audio Output Phase P2 Audio Output Phase P3SS Normal Play Speed 40 E 3-4 SetupSS LIP Sync Adjust SS Audio MutingExpansion Menu Operation System Time SettingsSuperimposed Character Information Character adjustmentDisplayed information Additional information displayed in the BVE mode BVE mode display is shown below Preparations for Recording Switch SettingsSelecting the audio signals to be monitored Selecting the Video SignalsSelecting the Audio Signals Selecting the video signals to be monitoredRecording Analog Audio Adjusting Recording LevelsTo adjust the recording level Using the emphasis functionDisplayed Preparations for PlaybackTo display user bits Selecting the Playback Port to be ControlledSelecting the Displayed Time Data To display time data To adjust the playback level manually Adjusting Playback Audio Levels Remotely Controlling Video Processor Changing the Motion Mode Basic Operation with SS ModeMotion Modes Playback Operation Changing the Operation ModeBasic Operation with Panel Mode Recording OperationBasic Operations with DTR+Panel and DTR+DTR Modes EE Signal SelectionInitial Setup for DTR+Panel and DTR+DTR Modes Setting the Recording Time from the DTRBasic Operations DTR+Panel and DTR+DTR Modes Port Configuration Basic Operations in BVE ModeBasic Operation of the RP Port Manual Recording through the RP Port When performing the operation through the MAVE-F555Loading a New File for Editing in the RP Port Linear Editing through the RP PortReplacing Files through the R2 Port Basic Operation of the R2 PortBasic Operation of the P2 and P3 Ports Collecting through the R2 PortPlayback through the P2 and P3 Ports When the R1 key was pressedNew File Names Monitoring the RP PortPre-roll Time File Backup FunctionEditing-Related Error Messages When the P1 key was pressed10 E 5-5 Basic Operations in BVE Mode Error Error MessagesFan1 Trouble RAID Com. ErrorRAID Error FM Battery WarningTemperature Rise RAID Battery WarningHDD xx SPC Error EM Mixer Config FailDigital video system SpecificationsGeneral OperationVideo system Processor adjustment rangesInput connectors Output connectorsMemory Card sold separately Remote connectorsSupplied accessories Optional accessoriesPage Sony Corporation