7. INITIAL SETTING OF ADJUSTMENT VALUE

7. INITIAL SETTING OF ADJUSTMENT VALUE

Note:

Mode which sets the adjustment results recorded in the non-volatile memory to the initial setting value. However the results of the tempera- ture compensation offset adjustment will not change to the initial setting value.

If initial setting is performed, perform all adjustments again excluding the temperature compensation offset adjustment.

For details of the initial setting, refer to “4. Precautions on Adjustments” and execute the initial setting before the adjustment as required.

Setting Procedure :

1.Turn the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob to display “ADJ CLEAR (C24)”.

2.Press the [YES] button. “Complete!” will be displayed mo- mentarily and initial setting will be executed, after which “ADJ CLEAR” will be displayed.

8. RECORDING AND DISPLAYING THE IOP INFORMATION

The IOP data can be recorded in the non-volatile memory. The IOP value on the label of the optical pickup and the IOP value after the adjustment will be recorded. Recording these data elimi- nates the need to read the label on the optical pick-up.

Recording Procedure :

1.Turn the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob to display “Iop Write” (C28), and press the [YES] button.

2.The display becomes Ref=@@@.@ (@ is an arbitrary num- ber) and the numbers which can be changed will blink.

3.Input the IOP value written on the optical pick-up.

To select the number : Turn the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob.

To select the digit : Press the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob

4.When the [YES] button is pressed, the display becomes “Measu=@@@.@” (@ is an arbitrary number).

5.As the adjustment results are recorded for the 6 value. Leave it as it is and press the [YES] button.

6.“Complete!” will be displayed momentarily. The value will be recorded in the non-volatile memory and the display will be- come “Iop Write”.

Display Procedure :

1.Turn the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob to display “Iop Read”(C27).

2.“@@.@/##.#” is displayed and the recorded contents are dis- played.

@@.@ indicates the IOP value labeled on the pick-up. ##.# indicates the IOP value after adjustment

3.To end, press the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± button or [MENU/NO] button to display “Iop Read”.

9. TEMPERATURE COMPENSATION OFFSET ADJUSTMENT

Save the temperature data at that time in the non-volatile memory as 25 ˚C reference data.

Note :

1.Usually, do not perform this adjustment.

2.Perform this adjustment in an ambient temperature of 22 ˚C to 28 ˚C. Perform it immediately after the power is turned on when the internal temperature of the unit is the same as the ambient temperature of 22 ˚C to 28 ˚C.

3.When D101 has been replaced, perform this adjustment after the tem- perature of this part has become the ambient temperature.

Adjusting Procedure :

1.Turn the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob and display “TEMP ADJUS” (C09).

2.Press the [YES] button and select the “TEMP ADJUS” mode.

3.“TEMP = Setting Procedure :8. RECORDING AND DISPLAYING THE IOP INFORMATIONRecording Procedure :Display Procedure : [OK” and the current temperature data will be displayed.

4.To save the data, press the [YES] button.

When not saving the data, press the [MENU/NO] button.

5.When the [YES] button is pressed, “TEMP = 9. TEMPERATURE COMPENSATION OFFSET ADJUSTMENTAdjusting Procedure : SAVE” will be displayed and turned back to “TEMP ADJUS” display then. When the [MENU/NO] button is pressed, “TEMP ADJUS” will be displayed immediately.

Specified Value :

The “TEMP = Specified Value :10. LASER POWER ADJUSTMENTConnection :laser power meter– 26 – ” should be within “E0 - EF”, “F0 - FF”, “00 - 0F”, “10 - 1F” and “20 - 2F”.

10. LASER POWER ADJUSTMENT

Check the IOP value of the optical pick-up before adjustments. (Refer to 8. Recording and Displaying IOP Information)

Connection :laser power meter

Optical pick-up objective lens Manual background

digital voltmeter

BD board

 

 

 

 

 

 

CN110 pin 5

(I +3V)

 

 

 

+

 

CN110 pin 4

(IOP)

 

Adjusting Procedure :

1.Set the laser power meter on the objective lens of the optical pick-up. (When it cannot be set properly, press the [ÊÊÊÊÊÊ]0 button or [ÊÊÊÊÊÊ]) button to move the optical pick-up.)

Connect the digital volt meter to CN110 pin 5 (I+3V) and CN110 pin 4 (IOP).

2.Turn the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob and display “LDPWR ADJUS” (C10).

(Laser power : For adjustment)

3.Press the [YES] button once and display “LD 0.9 mW $ Manual backgroundManual background ”.

4.Turn the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob so that the reading of the la- ser power meter becomes 0.85 to 0.91 mW. Press the [YES] button after setting the range knob of the laser power meter, and save the adjustment results. (“LD SAVE $ Manual backgroundManual background” will be dis- played for a moment.)

5.Then “LD 7.0 mW $ Manual backgroundManual background ” will be displayed.

6.Turn the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob so that the reading of the la- ser power meter becomes 6.9 to 7.1 mW, press the [YES]

button and save it.

Note: Do not perform the emission with 7.0 mW more than 15 seconds continuously.

– 26 –

Image 26
Contents Supplied accessories SPECIFICATIONSSERVICE MANUAL MDS-JE530SELF-DIAGNOSISFUNCTION – 2 –– 3 – Items of Error History Mode Items and ContentsTable of Error Codes Selecting the Test ModeDISASSEMBLY TABLE OF CONTENTS6.DIAGRAMS ELECTRICAL ADJUSTMENTS– 5 – Flexible Circuit Board RepairingNotes on chip component replacement ADVARSEL– 6 – JIG FOR CHECKING BD BOARD WAVEFORMDisplay Precedure – 7 –Record Precedure CHECKS PRIOR TO PARTS REPLACEMENT AND ADJUSTMENTS – 8 –Precedure – 9 –RETRY CAUSE DISPLAY MODE Fig. 1 Reading the Test Mode DisplayReading the Display – 10 –Hexadecimal nBinary Conversion Table LOCATION OF CONTROLS SECTION GENERAL– 11 – This section is extracted from instruction manualPage CASE SECTION DISASSEMBLY– 13 – FRONT PANEL SECTIONMECHANISM DECK SECTTION MDM-5D – 14 –MAIN BOARD BASE UNIT MBU-5D,BD BOARD – 15 –SLIDER CAM – 16 – SW BOARD, LOADING MOTOR M103SECTION TEST MODE 1. PRECAUTIONS FOR USE OF TEST MODE2. SETTING THE TEST MODE – 17 –– 18 – 5. SELECTING THE TEST MODE5-3. Non-VolatileMemory Mode EEP MODE – 19 –5-1.Operating the Continuous Playback Mode 7. TEST MODE DISPLAYS – 20 –6. FUNCTIONS OF OTHER BUTTONS – 21 – MEANINGS OF OTHER DISPLAYS– 22 – SECTION ELECTRICAL ADJUSTMENTS1.PARTS REPLACEMENT AND ADJUSTMENT Laser power meter 2. PRECAUTIONS FOR CHECKING LASER DIODE EMISSION4. PRECAUTIONS FOR ADJUSTMENTS – 23 –Specification Checking Procedure6-2.Laser Power Check – 24 –– 25 – 6-5.C PLAY Checking MO Error Rate CheckCD Error Rate Check 6-4.Focus Bias Check10. LASER POWER ADJUSTMENT 7. INITIAL SETTING OF ADJUSTMENT VALUE9. TEMPERATURE COMPENSATION OFFSET ADJUSTMENT Setting ProcedureSpecification 11. TRAVERSE ADJUSTMENT– 27 – Adjusting ProcedureAdjusting Procedure 12.FOCUS BIAS ADJUSTMENT– 28 – 13-1.CD Error Rate Check 13.ERROR RATE CHECK15.AUTO GAIN CONTROL OUTPUT LEVEL ADJUSTMENT 13-2.MO Error Rate Check– BD BOARDSide A – Adjustment Location– 30 – – BD BOARDSide B –– 31 – MDS-JE530 SECTION DIAGRAMS6-1.BLOCK DIAGRAM – MD SERVO Section – – 32 –– 33 – 6-2.BLOCK DIAGRAM – MAIN Section –MDS-JE530 – 34 –Note on Schematic Diagram – 35 –Note on Printed Wiring Board – 36 – • Circuit Boards Location•See page 36 for Circuit Boards Location 6-4.PRINTED WIRING BOARD – BD Board –– 38 – •Semiconductor LocationMDS-JE530 – 39 –– 40 – – 42 – 6-6.SCHEMATIC DIAGRAM – BD Board 2/2 – See•– 41 – MDS-JE530– 43 – 6-7.SCHEMATIC DIAGRAM – SW Board –6-8.PRINTED WIRING BOARD – SW Board – – 44 –– 46 – 6-9.PRINTED WIRING BOARD – MAIN Board – See•– 45 – page 36 for Circuit Boards LocationMDS-JE530 – 47 –– 48 – Page Page 41 PageMDS-JE530 – 49 –– 50 – MDS-JE530 – 51 –– 52 – • Semiconductor LocationMDS-JE530 – 53 –– 54 – Page 47 Page– 56 – •IC Block Diagrams – BD Board –– 55 – IC101M5293L – 57 –IC310 IC431– 58 – 6-14.IC PIN FUNCTION DESCRIPTION– 59 – •BD BOARD IC121 CXD2656R– 60 – – 61 – – 62 – •MAIN BOARD IC501 M30624MG-207FPSYSTEM CONTROLLER– 63 – – 64 – 1CHASSIS SECTION SECTION EXPLODED VIEWS– 65 – 51 53 2FRONT PANEL SECTION 61 64 61 63 6166 61 61 59 54 52202 201 – 67 –3MECHANISM SECTION MDM-5D 213 207 223 207263 270 – 68 –4BASE UNIT SECTION MBU-5D 252 254 253SECTION ELECTRICAL PARTS LIST – 69 –DISPLAY – 70 –DISPLAY KEY SW– 71 – KEY SW MAIN– 72 – – 73 – MAIN– 74 – MAINMAIN POWER SW– 75 – Sony Corporation MDS-JE530– 76 – 9-928-824-11