Graco 311511G important safety instructions Key

Page 11

Key:

RMain Disconnect Switch - Controls power to all circuits. It must be ON for proportioning unit to operate. Temperature displays are lit when main switch is ON.

SMain Air Filter - Filters system air supply.

TResin (B) Pressure Gauge - Displays pressure in resin proportioning system (B side).

UResin (B) - Inlet Supply Valve

VResin (B) Fluid Y-Strainer

WISO (A) Pressure Gauge - Displays pressure in isocyanate proportioning system (A side).

XISO (A) - Inlet Supply Valve

YISO (A) Fluid Y-Strainer

ZISO (A) Pump Lube System - (A side only)

AAISO (A) - Packing Nut and Lube Cup - (A side only)

*ABPressure Limit Switches - Factory set to turn off air drive system when proportioning pump exceeds designed operating pressure limit.

*ACPrimary Heater Thermocouple - Senses temperature of primary heater and inputs that information.

AD FTS Jumper Harness - Carries electrical signal from FTS sensor in isocyanate hose to hose temperature controller.

*AEAir Motor Reversing Switch - (Front of air motor) Energizes and de-energizes air solenoid valve coils to reverse direction.

*AF Primary Heater - Heats material to required dispensing temperature.

AG ISO (A) - (Isocyanate) Proportioning Pump - Draws in and dispenses a fixed volume of isocyanate to gun.

Component Identification

AH Resin (B) Proportioning Pump - Draws in and dispenses a fixed volume of resin to gun.

AI Power-LockHose Heat Connection - Connects

power to heated hoses.

*AJ Primary Heater Over-Temperature Switch - Sends signal to temperature controller if heater exceeds maximum temperature condition.

AK Resin (B) Pump Wet Cup - Access for daily wet cup refill.

DDAir Inlet Ball Valve - (3/8 NPT male fitting)

FF ISO (A) Inlet - Fitting (1/2 swivel fitting)

GG Resin (B) - Inlet (3/4 swivel fitting)

* Components not shown.

311511G

11

Image 11
Contents Reactor A-20 Related Manuals ContentsApprovals SystemsProportioner 50 ft 15 m 10 ft 3 m PartElectric Shock Hazard Fire and Explosion Hazard Moving Parts Hazard Key for FIG Typical Installation, without CirculationTypical Installation, with Circulation Keep Components a and B Separate Moisture Sensitivity of IsocyanatesFoam Self-Ignition Isocyanate HazardComponent Identification Typical InstallationKey AP Park/Run Switch Controls and IndicatorsFlushing Pressure Relief ProcedureLocate Reactor A-20 Electrical Requirements SetupDetermine Power Source Step One Connect Electrical Cord Configure to Supply PowerTerminal Blocks Power Jumper LocationAir Supply Connection Iso Pump Lubrication System SetupGround System Fluid Supply ConnectionsConnect FTS and Heated Dual Whip Hose Connect Heated Hose Recirculation / Pressure Relief LinesPressure Check Hose Close Gun Fluid Manifold Valves a and BConnect Whip Hose to Gun Fluid Manifold Load Fluid with Feed Pumps Fluid Temperature Sensor FTS CalibrationInitial Startup A1 A2 A3 Digital Temperature ControllersTo change or enter the set point, proceed as follows To change back to Fahrenheit units To change to Celsius unitsHose Heat Manual Mode Over Temperature AlarmsFluid Heater Temperature Offset Supply Wet-Cups with Throat Seal Liquid Spray Spraying SetupSpray Adjustments Shutdown Operation Daily Start-up ProcedureTi2414A Circulation Through Reactor Fluid CirculationCKN Circulation Through Gun ManifoldMaintenance Category Data Technical DataTechnical Data 311511G Graco Information Graco Standard Warranty