Graco 311511G important safety instructions Pressure Relief Procedure, Flushing

Page 13

Pressure Relief

Procedure

1.Turn off feed pumps and agitator if used.

2.Turn PARK/RUN switch to PARK.

3.Trigger gun to relieve pressure.

4.Turn off air inlet valve.

5.Engage gun piston safety lock.

ti2409a

6. Verify gun fluid manifold valves A and B are closed.

ti2421a

7. Close pump inlet supply valves.

Pressure Relief Procedure

Flushing

Flush equipment only in a well-ventilated area. Do not spray flammable fluids. Do not turn on heaters while flushing with flammable solvents.

Flush out old fluid with new fluid, or flush out old fluid with a compatible solvent, such as toluene, naptha, or mineral spirits before introducing new fluid.

Use lowest possible pressure when flushing.

To flush entire system, circulate through gun fluid manifold (with manifold removed from gun).

Always leave hydraulic oil or a non-water based, non-water absorbent fluid in system. Do not use water.

Only use flush solvents that are compatible with Fluo- roelastomer seals. Non-compatible solvents will dam- age seals and cause hazardous conditions, such as high pressure leaks and pressure switch failure.

311511G

13

Image 13
Contents Reactor A-20 Related Manuals ContentsProportioner 50 ft 15 m 10 ft 3 m SystemsPart ApprovalsElectric Shock Hazard Fire and Explosion Hazard Moving Parts Hazard Key for FIG Typical Installation, without CirculationTypical Installation, with Circulation Foam Self-Ignition Moisture Sensitivity of IsocyanatesIsocyanate Hazard Keep Components a and B SeparateComponent Identification Typical InstallationKey AP Park/Run Switch Controls and IndicatorsFlushing Pressure Relief ProcedureDetermine Power Source SetupLocate Reactor A-20 Electrical Requirements Step One Connect Electrical Cord Configure to Supply PowerTerminal Blocks Power Jumper LocationGround System Iso Pump Lubrication System SetupFluid Supply Connections Air Supply ConnectionConnect FTS and Heated Dual Whip Hose Connect Heated Hose Recirculation / Pressure Relief LinesConnect Whip Hose to Gun Fluid Manifold Close Gun Fluid Manifold Valves a and BPressure Check Hose Initial Startup Fluid Temperature Sensor FTS CalibrationLoad Fluid with Feed Pumps To change or enter the set point, proceed as follows Digital Temperature ControllersA1 A2 A3 To change back to Fahrenheit units To change to Celsius unitsFluid Heater Temperature Offset Over Temperature AlarmsHose Heat Manual Mode Supply Wet-Cups with Throat Seal Liquid Spray Spraying SetupSpray Adjustments Shutdown Operation Daily Start-up ProcedureTi2414A Circulation Through Reactor Fluid CirculationCKN Circulation Through Gun ManifoldMaintenance Category Data Technical DataTechnical Data 311511G Graco Information Graco Standard Warranty