Graco 311511G important safety instructions Technical Data, Category Data

Page 34

Technical Data

Technical Data

Category

Data

Maximum Fluid Working Pressure

2000 psi (1.4 MPa, 140 bar)

 

 

Maximum Air Working Pressure

120 psi (0.84 MPa, 8.4 bar)

 

 

Machine Maximum Power with hose

9000 Watts

 

 

Voltage Requirement (50/60 Hz)

230 V, 1 Phase

(230 V Nominal: 195-253 VAC)

230 V, 3 Phase (Delta)

(380 V Nominal: 338-457 VAC)

380 V, 3 Phase (WYE 220 V Neutral)

 

 

Amperage Requirement (Full Load Peak)*

40 amps @ 230 V, 1 Phase

 

32 amps @ 230 V, 3 Phase

 

18.5 amps @ 380 V, 3 Phase

 

 

Maximum Heater Fluid Temperature

190 °F (88 °C)

 

 

Maximum Hose Fluid Temperature

180 °F (82 °C)

 

 

Maximum Ambient Temperature

120 °F (49 °C)

 

 

Maximum Output

20 lb/min. (9.0 kg/min.)

 

 

Output Per Cycle (A and B)

.028 gal/cycle (.105 ltr/cycle)

 

 

Overpressure Relief Shutdown

2250 psi (15.5 MPa, 155 bar)

 

 

Over Temperature Shutdown (Primary Heater)

230 °F (110 °C)

 

 

Heater Power

6000 Watts

 

 

Hose Power

2790 Watts

 

 

Sound Pressure

86.3 dB(A) at 2000 psi (14 MPa, 140 bar), 0.5 gpm (1.9 lpm)

 

 

Sound Power, per ISO 9614-2

91.6 dB(A) at 2000 psi (14 MPa, 140 bar), 0.5 gpm (1.9 lpm)

 

 

Viscosity Range

250-1500 centipoise

 

 

Maximum Fluid Inlet Pressure

400 psi (2.7 MPa, 27 bar)

 

 

Fluid Inlet/Strainer Filter

20 mesh standard

 

 

Air inlet Filter Mesh

5 Micron

 

 

Component B (Resin) Inlet

3/4 npt(f) swivel

 

 

Component A (Isocyanate) Inlet

1/2 npt(f) swivel

 

 

Recirculation/Block Hose Connections

Iso (A) side: #5 JIC (m); Resin (B) side: #6 JIC (m)

 

 

Maximum Heated Hose Length***

210 ft of 3/8 ID

 

 

Height

39.5 in. (1003.3 cm)

 

 

Width

27.2 in. (690.9 cm)

 

 

Depth

25.0 in. (635 cm)

 

 

Weight

250 lb (117.6 kg)

 

 

Wetted Parts

Carbon steel, stainless steel, chrome, aluminum,

 

Fluoroelastomer, PTFE, nylon

 

 

Certification

CE **

 

 

*Full load amps with all devices operating at maximum capabilities with 210 ft (64.1 m) of hose.

**When a surge transient is applied to the power lines of the unit, heat to the hose may be interrupted and require the hose heat switch to be manually cycled.

***210 ft (64 m) of heated hose will produce the maximum allowable heat capacity. 310 ft (94 m) of heated hose may be used, but will have 25% less heat capacity.

34

311511G

Image 34
Contents Reactor A-20 Contents Related ManualsPart SystemsProportioner 50 ft 15 m 10 ft 3 m ApprovalsElectric Shock Hazard Fire and Explosion Hazard Moving Parts Hazard Typical Installation, without Circulation Key for FIGTypical Installation, with Circulation Isocyanate Hazard Moisture Sensitivity of IsocyanatesFoam Self-Ignition Keep Components a and B SeparateTypical Installation Component IdentificationKey Controls and Indicators AP Park/Run SwitchPressure Relief Procedure FlushingDetermine Power Source SetupLocate Reactor A-20 Electrical Requirements Configure to Supply Power Step One Connect Electrical CordPower Jumper Location Terminal BlocksFluid Supply Connections Iso Pump Lubrication System SetupGround System Air Supply ConnectionConnect FTS and Heated Dual Whip Hose Recirculation / Pressure Relief Lines Connect Heated HoseConnect Whip Hose to Gun Fluid Manifold Close Gun Fluid Manifold Valves a and BPressure Check Hose Initial Startup Fluid Temperature Sensor FTS CalibrationLoad Fluid with Feed Pumps To change or enter the set point, proceed as follows Digital Temperature ControllersA1 A2 A3 To change to Celsius units To change back to Fahrenheit unitsFluid Heater Temperature Offset Over Temperature AlarmsHose Heat Manual Mode Supply Wet-Cups with Throat Seal Liquid Spraying Setup SpraySpray Adjustments Shutdown Daily Start-up Procedure OperationTi2414A Fluid Circulation Circulation Through ReactorCirculation Through Gun Manifold CKNMaintenance Technical Data Category DataTechnical Data 311511G Graco Standard Warranty Graco Information