Graco 311511G important safety instructions Circulation Through Gun Manifold, Ckn

Page 32

Fluid Circulation

Circulation Through Gun Manifold

Read Warnings; see page 4. Do not circulate fluid containing a blowing agent without consulting with your material supplier regarding fluid temperature limits.

Circulating fluid through the gun manifold allows rapid preheating of hose.

1.Install gun fluid manifold (FM) on Part 246362 accessory circulation kit (CK).

FM

CKN

ti2767a

2.Connect high pressure circulation lines (N) to circulation manifold (CK). Route circulation lines back to respective component A or B supply drum. Use hoses rated at the maximum working pressure of this equipment.

3.Follow Load Fluid with Feed Pumps procedure; see page 21.

4.Turn Main Power Disconnect Switch (R) ON.

5.Open air inlet ball valve.

6.Set temperature targets; see page 22. Turn on heater.

Do not turn on hose heat unless hoses are already loaded with fluid.

7.Set both Air Regulator pressures to start at 15 psi (1.0 bar).

8.Turn PARK/RUN switch to RUN.

9.Turn Pump Mode Function switch to START.

10.Recirculate until desired temperature reaches set point.

11.Turn Pump Mode Function switch to OFF.

12.Close gun fluid manifold valves.

13.Reconnect gun to fluid manifold and air hose.

For additional recirculation information, refer to manual 309818.

32

311511G

Image 32 Contents
Reactor A-20 Contents Related ManualsSystems Proportioner 50 ft 15 m 10 ft 3 mPart ApprovalsElectric Shock Hazard Fire and Explosion Hazard Moving Parts Hazard Typical Installation, without Circulation Key for FIGTypical Installation, with Circulation Moisture Sensitivity of Isocyanates Foam Self-IgnitionIsocyanate Hazard Keep Components a and B SeparateTypical Installation Component IdentificationKey Controls and Indicators AP Park/Run SwitchPressure Relief Procedure FlushingLocate Reactor A-20 Electrical Requirements SetupDetermine Power Source Configure to Supply Power Step One Connect Electrical CordPower Jumper Location Terminal BlocksIso Pump Lubrication System Setup Ground SystemFluid Supply Connections Air Supply ConnectionConnect FTS and Heated Dual Whip Hose Recirculation / Pressure Relief Lines Connect Heated HosePressure Check Hose Close Gun Fluid Manifold Valves a and BConnect Whip Hose to Gun Fluid Manifold Load Fluid with Feed Pumps Fluid Temperature Sensor FTS CalibrationInitial Startup A1 A2 A3 Digital Temperature ControllersTo change or enter the set point, proceed as follows To change to Celsius units To change back to Fahrenheit unitsHose Heat Manual Mode Over Temperature AlarmsFluid Heater Temperature Offset Supply Wet-Cups with Throat Seal Liquid Spraying Setup SpraySpray Adjustments Shutdown Daily Start-up Procedure OperationTi2414A Fluid Circulation Circulation Through ReactorCirculation Through Gun Manifold CKNMaintenance Technical Data Category DataTechnical Data 311511G Graco Standard Warranty Graco Information