Pelco IP110 manual 4S Electrical BOX Installation, Electrical Box Installation

Page 13

4S ELECTRICAL BOX INSTALLATION

1.Attach an ICS110-AP adapter plate (not supplied) to a 4S electrical box. Use two 8-32 x 0.75-inch Phillips flat head screws (supplied with both the IP110 and the adapter plate).

2.Remove the two 8-32 x 0.375-inch Phillips pan head screws and washers to separate the cover from the back box.

3.Pull the cable and wires into the cover.

4.Attach the cover to the adapter plate with four 8-32 x 0.375-inch Phillips pan head screws (supplied with the adapter plate). Use stainless steel hardware when installing the system outdoors.

5.Install the camera module into the back box before installing the back box into the cover. Rotate the camera module to access the mounting holes inside the back box (refer to Camera Module on page 19 for more information).

6.Connect the cable and wires (refer to Wiring Tables on page 16 for information).

7.Reinstall the back box inside the cover. Use the two 8-32 x 0.375-inch Phillips pan head screws and washers (removed earlier) to secure the back box to the cover.

4S STANDARD ELECTRICAL BOX

CEILING/

WALL

8-32 X 0.75-INCH

ADAPTER PLATE

PHILLIPS FLAT

HEAD SCREWS

(ICS110-AP)

(SUPPLIED)

 

COVER

8-32 X 0.375-INCH PHILLIPS PAN HEAD SCREWS (SUPPLIED WITH ICS110-AP)

BACK BOX

8-32 X 0.375-INCH PHILLIPS PAN HEAD SCREWS WITH WASHERS (SUPPLIED)

Figure 6. 4S Electrical Box Installation

C3432M-G (4/09)

13

Image 13
Contents IP110 Series Camclosure Page Contents List of Illustrations List of Tables Important Safety Instructions Radio and Television Interference Regulatory NoticesOpen Source Software Notice Description Parts ListModels Dhcp Network Example Basic System ConfigurationsPrivate Network Example Basic Surface Installation Cover and Back Box InstallationElectrical Box Installation 4S Electrical BOX InstallationPlaster Ring Installation Plaster Ring InstallationSide Conduit Installation Side Conduit InstallationCAT5 Cable Wiring TablesRefer to for pin descriptions PoEAlarm and 24 VAC Wires Connecting Alarms Camera Orientation Camera ModuleCamera Module Bracket Module InstallationTo perform camera adjustments Camera AdjustmentsLocation of Zoom and Focus Locking Screws Varifocal Lens Zoom and Focus AdjustmentsAdjusting the Focus To adjust the focus Loosen the focus locking screwRefer to to adjust the IP110-DN or IP110-CH model DN/CH Series AdjustmentsBlemish Detection DAY/NIGHT Operation Refer to to adjust the IP110-DW or IP110-CW model DW/CW Series Wide Dynamic Range AdjustmentsSW1-4 Auto White Balance/Manual White Balance Auto Iris Level Adjustment Positioning the Camera Camera PositioningInstall Dome and Trim Ring Service Connector Service ConnectorAttaching the 2.5 mm Monaural Headphone Plug Reset Button Troubleshooting IR cut filter setting Check DIP switch settings Table F. Troubleshooting the IP110 Series 2Green LED during camera power up IR cut filter is functioningNetwork not Faulty cable Table F. Troubleshooting the IP110 Series 3Configuration Router with an n-Port switchImpact SpecificationsCable Entry Cm openings on Nema cover176 x Bit Rate Configurable Signal SystemSignal System Ntsc or PAL Scanning System 704 xType LensC3432M-G 4/09 Revision History Product Warranty and Return Information