Pelco IP110 manual Reset Button

Page 34

Reset Button

Use the reset button located on the board inside the back box to access the following modes described in Table E.

Table E. Reset Button Modes and Descriptions

Mode

Function

Unit Status Indicator Light

 

 

 

Configuration

Starts the reset LED

Flashes green.

 

selection sequence.

 

 

 

 

Reboot

Restarts the unit.

Flashes green and red simultaneously, when entering

 

 

this mode. The LED then flashes green when mode is

 

 

selected and during the reboot.

Reset

Resets the unit to factory

Flashes red when entering this mode. Flashes red

 

default settings, and then

when the mode is selected, and then flashes green

 

restarts the unit.

when the camera restarts. The camera is off line

 

 

during reset mode.

 

 

 

Cancel

Cancels any configuration

No light.

 

or reset action.

 

 

 

 

To access one of these modes:

1.Press and hold the reset button. The unit starts cycling through the modes; hold the button for four seconds to access (cycle through) each mode. The unit status indicator flashes the color for the current mode (refer to the table above).

2.When the color of the desired mode appears, release the button.

NOTES:

If there is no configuration activity for 15 minutes, the camera will automatically exit the reset mode.

The LED is not lit during normal operation.

RESET

BUTTON

RED / GREEN LEDS

Figure 25. Location of Reset Button and LEDs

34

C3432M-G (4/09)

Image 34
Contents IP110 Series Camclosure Page Contents List of Illustrations List of Tables Important Safety Instructions Regulatory Notices Radio and Television InterferenceOpen Source Software Notice Description Parts ListModels Basic System Configurations Dhcp Network ExamplePrivate Network Example Cover and Back Box Installation Basic Surface Installation4S Electrical BOX Installation Electrical Box InstallationPlaster Ring Installation Plaster Ring InstallationSide Conduit Installation Side Conduit InstallationRefer to for pin descriptions Wiring TablesCAT5 Cable PoEAlarm and 24 VAC Wires Connecting Alarms Camera Module Camera OrientationModule Installation Camera Module BracketCamera Adjustments To perform camera adjustmentsVarifocal Lens Zoom and Focus Adjustments Location of Zoom and Focus Locking ScrewsTo adjust the focus Loosen the focus locking screw Adjusting the FocusDN/CH Series Adjustments Refer to to adjust the IP110-DN or IP110-CH modelBlemish Detection DAY/NIGHT Operation DW/CW Series Wide Dynamic Range Adjustments Refer to to adjust the IP110-DW or IP110-CW modelSW1-4 Auto White Balance/Manual White Balance Auto Iris Level Adjustment Camera Positioning Positioning the CameraInstall Dome and Trim Ring Service Connector Service ConnectorAttaching the 2.5 mm Monaural Headphone Plug Reset Button Troubleshooting Green LED during camera power up Table F. Troubleshooting the IP110 Series 2IR cut filter setting Check DIP switch settings IR cut filter is functioningConfiguration Table F. Troubleshooting the IP110 Series 3Network not Faulty cable Router with an n-Port switchCable Entry SpecificationsImpact Cm openings on Nema coverSignal System Ntsc or PAL Scanning System Signal System176 x Bit Rate Configurable 704 xLens TypeC3432M-G 4/09 Revision History Product Warranty and Return Information