To adjust the focus:

1.Loosen the focus locking screw.

2.Position the inverted dome approximately 0.125 inch (3.175 mm) from the front of the lens. Make sure that the lens and the dome are centered (refer to Figure 16).

3.Turn the focus locking screw clockwise or counterclockwise to adjust the focus.

4.When the optimal focus is reached, tighten the focus locking screw.

ZOOM

FOCUS 0.125 INCH (3.175 mm)

CENTER BUBBLE

WITH LENS

Figure 16. Adjusting the Focus

C3432M-G (4/09)

23

Image 23
Contents IP110 Series Camclosure Page Contents List of Illustrations List of Tables Important Safety Instructions Radio and Television Interference Regulatory NoticesOpen Source Software Notice Models Parts ListDescription Dhcp Network Example Basic System ConfigurationsPrivate Network Example Basic Surface Installation Cover and Back Box InstallationElectrical Box Installation 4S Electrical BOX InstallationPlaster Ring Installation Plaster Ring InstallationSide Conduit Installation Side Conduit InstallationPoE Wiring TablesCAT5 Cable Refer to for pin descriptionsAlarm and 24 VAC Wires Connecting Alarms Camera Orientation Camera ModuleCamera Module Bracket Module InstallationTo perform camera adjustments Camera AdjustmentsLocation of Zoom and Focus Locking Screws Varifocal Lens Zoom and Focus AdjustmentsAdjusting the Focus To adjust the focus Loosen the focus locking screwRefer to to adjust the IP110-DN or IP110-CH model DN/CH Series AdjustmentsBlemish Detection DAY/NIGHT Operation Refer to to adjust the IP110-DW or IP110-CW model DW/CW Series Wide Dynamic Range AdjustmentsSW1-4 Auto White Balance/Manual White Balance Auto Iris Level Adjustment Positioning the Camera Camera PositioningInstall Dome and Trim Ring Service Connector Service ConnectorAttaching the 2.5 mm Monaural Headphone Plug Reset Button Troubleshooting IR cut filter is functioning Table F. Troubleshooting the IP110 Series 2IR cut filter setting Check DIP switch settings Green LED during camera power upRouter with an n-Port switch Table F. Troubleshooting the IP110 Series 3Network not Faulty cable ConfigurationCm openings on Nema cover SpecificationsImpact Cable Entry704 x Signal System176 x Bit Rate Configurable Signal System Ntsc or PAL Scanning SystemType LensC3432M-G 4/09 Revision History Product Warranty and Return Information