Pelco IP110 manual Alarm and 24 VAC Wires

Page 17

ALARM AND 24 VAC WIRES

 

Table B. Wire Descriptions

 

 

Wire Color

Description

 

 

Black

24 VAC (use only if PoE is not connected)

 

 

Red

24 VAC (use only if PoE is not connected)

 

 

Blue

Alarm In

 

 

Blue/White

Alarm In, Return

 

 

Green

Relay Out

 

 

Green/White

Relay Out, Return

 

 

CONNECTING A RELAY DEVICE

The IP110 Camclosure has an output for triggering an external device. It supports both momentary and continuous relay operation.

You can operate the relay interactively, during an active connection, or automatically to coincide with certain events. Typical applications include activating a door, gate or lock, or switching on lights or other electrical devices.

WARNING: Do not exceed the maximum rating of 12 VDC, 0.15 A.

Figure 10 shows how to wire the relay with its power source to the Camclosure.

CONNECTING A RELAY DEVICE

(CONNECTION EXAMPLE)

DC

GREEN WIRE

GREEN / WHITE WIRE

_ +

Figure 10. Relay Wiring

NOTE: The green/white wire is internally connected to the Camclosure chassis. Any connected signaling device should remain floating with respect to the Camclosure chassis; otherwise damage could result.

C3432M-G (4/09)

17

Image 17
Contents IP110 Series Camclosure Page Contents List of Illustrations List of Tables Important Safety Instructions Radio and Television Interference Regulatory NoticesOpen Source Software Notice Models Parts ListDescription Dhcp Network Example Basic System ConfigurationsPrivate Network Example Basic Surface Installation Cover and Back Box InstallationElectrical Box Installation 4S Electrical BOX InstallationPlaster Ring Installation Plaster Ring InstallationSide Conduit Installation Side Conduit InstallationCAT5 Cable Wiring TablesRefer to for pin descriptions PoEAlarm and 24 VAC Wires Connecting Alarms Camera Orientation Camera ModuleCamera Module Bracket Module InstallationTo perform camera adjustments Camera AdjustmentsLocation of Zoom and Focus Locking Screws Varifocal Lens Zoom and Focus AdjustmentsAdjusting the Focus To adjust the focus Loosen the focus locking screwRefer to to adjust the IP110-DN or IP110-CH model DN/CH Series AdjustmentsBlemish Detection DAY/NIGHT Operation Refer to to adjust the IP110-DW or IP110-CW model DW/CW Series Wide Dynamic Range AdjustmentsSW1-4 Auto White Balance/Manual White Balance Auto Iris Level Adjustment Positioning the Camera Camera PositioningInstall Dome and Trim Ring Service Connector Service ConnectorAttaching the 2.5 mm Monaural Headphone Plug Reset Button Troubleshooting IR cut filter setting Check DIP switch settings Table F. Troubleshooting the IP110 Series 2Green LED during camera power up IR cut filter is functioningNetwork not Faulty cable Table F. Troubleshooting the IP110 Series 3Configuration Router with an n-Port switchImpact SpecificationsCable Entry Cm openings on Nema cover176 x Bit Rate Configurable Signal SystemSignal System Ntsc or PAL Scanning System 704 xType LensC3432M-G 4/09 Revision History Product Warranty and Return Information