Installation

Wiring Guidelines for the NXD-500i Panel

The NXD-500i panel utilizes the Power over Ethernet protocol, where it draws power directly from its Ethernet connection. Because of this, the panel has no need for standard power inputs or outputs.

Ethernet/RJ-45 Port: Connections and Wiring

FIG. 12 describes the blink activity for the Ethernet 10/100 Base-T RJ-45 connector and cable. The Ethernet cable is connected to the side of the Wall Mount panels.

A - Activity LED (yellow)

A

 

 

 

 

 

 

 

 

 

 

 

 

 

L

lights when receiving or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

transmitting Ethernet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

data packets

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ETHERNET

 

 

10/100

 

 

 

FIG. 12 Ethernet connector (showing communication and connection LEDs)

L - Link LED (green) lights when the Ethernet cables are connected and terminated correctly.

The following table lists the pinouts, signals, and pairing for the Ethernet connector.

Ethernet RJ-45 Pinouts and Signals

Pin

Signals

Connections

Pairing

 

Color

 

 

 

 

 

 

 

1

TX +

1 ---------

1

1 ---------

2

Orange-White

 

 

 

 

 

 

 

2

TX -

2 ---------

2

 

 

Orange

 

 

 

 

 

 

 

3

RX +

3 ---------

3

3 ---------

6

Green-White

 

 

 

 

 

 

 

4

PoE power

4 ---------

4

 

 

Blue

 

 

 

 

 

 

 

5

PoE power

5 ---------

5

4 ---------

5

Blue-White

 

 

 

 

 

 

 

6

RX -

6 ---------

6

 

 

Green

 

 

 

 

 

 

 

7

PoE power

7 ---------

7

7 ---------

8

Brown-White

 

 

 

 

 

 

 

8

PoE power

8 ---------

8

 

 

Brown

 

 

 

 

 

 

 

FIG. 13 diagrams the RJ-45 pinouts and signals for the Ethernet RJ-45 connector and cable.

FIG. 13 RJ-45 wiring diagram