Installation

Installing an NXD-500i into a Rack Mount Kit (NXA-RK5)

The NXA-RK5 is a 19" (48.26 cm) wide metal rack-mount (with black matte finish) measuring 3 rack units high.

1.Remove the Faceplate/Trim Ring assembly from the main NXD-500i unit.

2.Thread the incoming Ethernet and USB wiring from their terminal sources through the surface opening, leaving enough slack in the wiring to accommodate any re-positioning of the panel.

3.Connect all data and power wiring connectors to their corresponding locations along the left side of the device.

The USB connectors can be from either a USB extension cable or a wireless USB RF transmitter.

4.Test the incoming wiring by connecting the panel connections to their terminal locations. Verify that the panel is receiving power from the PoE Injector and functioning properly.

Do not disconnect the connectors from the touch panel. The unit must be installed with the necessary connectors before being inserted into the equipment rack.

5.Carefully insert the device into the NXA-RK5.

6.Secure the panel to the NXA-RK5 mount by first inserting and then tightening the three included #4-40 screws.

7.Insert the NXA-RK5 (with the connected NXD-500i unit) into the equipment rack, making sure to align the screw holes along the sides on the NXA-RK5 with the holes in the equipment rack.

8.Use a grounded Phillips-head screwdriver to secure the NXA-RK5 to the equipment rack using the included #10-32 screws.

9.Place the Faceplate/Trim Ring assembly back onto the main NXD-500i device. Make sure to align the Microphone, Light, and PIR Motion sensor locations to their respective openings on the front faceplate/bezel.

10.Reconnect the terminal Ethernet and USB wiring to their respective terminal locations on the Ethernet port or NetLinx Master.

NXD-500i 5" Wall/Flush Mount Touch Panel with Intercom

17

 

 

Page 23
Image 23
AMX manual Installing an NXD-500i into a Rack Mount Kit NXA-RK5