AMX NXD-500i manual Button Commands Cont, Programming, entry is required

Models: NXD-500i

1 148
Download 148 pages 52.91 Kb
Page 98
Image 98
(entry is required).

Programming

"^" Button Commands (Cont.)

^BIM

Syntax:

Set the input

"'^BIM-<vt addr range>,<input mask>'"

mask for the

Variable:

specified address.

 

variable text address range = 1 - 4000.

 

input mask = Refer to theText Area Input Masking section on page 136 for character

 

types.

 

Example:

 

SEND_COMMAND Panel,"'^BIM-500,AAAAAAAAAA'"

 

Sets the input mask to ten ’A’ characters, that are required, to either a letter or digit

 

(entry is required).

 

 

^BLN

The maximum number of lines to remove is 240. A value of 0 will display the incoming

Set the number of

video signal unaffected. This command is used to scale non 4x3 video images into non

lines removed

4x3 video buttons.

equally from the

Syntax:

top and bottom of

"'^BLN-<vt addr range>,<button states range>,<number of lines>'"

a composite video

Variable:

signal.

variable text address range = 1 - 4000.

 

 

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons

 

1 = Off state and 2 = On state).

 

number of lines = 0 - 240.

 

Example:

 

SEND_COMMAND Panel,"'^BLN-500,55'"

 

Equally removes 55 lines from the top and 55 lines from the bottom of the video button.

 

 