AMX NXD-500i manual Troubleshooting Information

Models: NXD-500i

1 148
Download 148 pages 52.91 Kb
Page 137
Image 137
Troubleshooting

Troubleshooting

Troubleshooting

This section describes the solutions to possible hardware/firmware issues that could arise during the common operation of a Modero touch panel.

Troubleshooting Information

Symptom

Solution

 

 

My USB drivers has a yellow

The USB driver was incorrectly installed and should be re-installed:

exclamation point and doesn’t

• Power up the panel without the USB cable connected to the panel.

appear to be working.

• Plug in the USB cable into the G4 panel. You should see a USB icon

 

 

show up in the System Tray.

 

• Double click on the icon to bring up the list of USB devices (you

 

should see the "AMX USB LAN LINK" device in the list).

 

• If the "Install Driver" dialog doesn't appear automatically, select the

 

"Properties" button and then the "Update Driver" button.

 

• When the Install Driver dialog does appear, click Next to accept all

 

the default prompts.

 

• The OS will state that the driver you are installing/updating does not

 

have a digital signature. This is acceptable, so agree to continue the

 

installation.

 

• After installation is complete, the exclamation point should disappear.

 

 

When using G4 WebControl to

• During a WebControl connection to a target panel, a G4

communicate with a target panel, a

Authentication dialog will ask you to enter the assigned password for

VNC Server dialog appears on my

the panel before allowing access.

screen.

• If prompted with a VNC Server dialog, enter the IP Address of the

 

target panel. This can be found within the Setup > Protected Setup

 

> System Connection page. This IP Address of the panel appears

 

within the IP Settings section of this page

 

• Enter the IP Address and click OK. When prompted with the G4

 

Authentication popup, enter the panel’s WebControl password.

 

 

While attempting to communicate

• A Green communication icon indicates that a connection has been

directly with the Virtual Master (on

established to the target Master or target Virtual Master.

the PC) via a USB connection, I

• Launch NetLinx Studio and configure the Master Connection

can’t get my communication icon

communication settings for a Virtual Master.

to turn Green.

• Navigate to the System connection page and toggle the Type field to

 

 

USB.

 

• Make sure the Type-A USB connector is securely connected to the

 

PC.

 

• Make sure the panel DOES NOT have the mini-USB connected and

 

then TURN OFF the panel.

 

• Once the panel has turned ON, THEN connect the mini-USB to the

 

Program Port. The USB icon should appear in the system tray. If it

 

doesn’t, refer to the Configuring and Using USB with a Virtual

 

Master section on page 25.

 

• The panel may need a few minutes to detect the connection to the

 

PC.

 

 

My Modero panel isn’t appearing

• Verify that the System number is the same on both the NetLinx

in my Workspace window.

Workspace window and the System Connection page on the Modero

 

panel.

 

• Verify that you have entered the proper NetLinx Master IP and

 

connection methods into the Master Connection section of the

 

System Connection page.

 

 

NXD-500i 5" Wall/Flush Mount Touch Panel with Intercom

131

 

 

Page 137
Image 137
AMX NXD-500i manual Troubleshooting Information, doesn’t, refer to the Configuring and Using USB with a Virtual