AMX NXD-500i manual Button Commands Cont, Programming, 0 = Normal, 1 = Invert horizontal axis

Models: NXD-500i

1 148
Download 148 pages 52.91 Kb
Page 108
Image 108
0 = Normal

Programming

"^" Button Commands (Cont.)

^GIV

Parameters 1,2, and 3 will cause a bargraph or slider to be inverted regardless of

Invert the

orientation. Their effect will be as described for joysticks.

Syntax:

 

 

joystick axis to

 

 

move the origin to

"'^GIV-<vt addr range>,<joystick axis to invert>'"

another corner.

Variable:

 

 

 

 

 

 

variable text address range = 1 - 4000.

 

joystick axis to invert = 0 - 3.

 

 

 

 

 

0 = Normal

 

 

0

 

1

 

 

 

 

 

1 = Invert horizontal axis

 

 

 

 

 

 

 

 

 

 

2 = Invert vertical axis

 

 

2

 

3

 

 

 

3 = Invert both axis locations

 

For a bargraph 1 = Invert , 0 = Non Invert

 

Example:

 

 

 

SEND_COMMAND Panel,"'^GIV-500,3'"

 

Inverts the joystick axis origin to the bottom right corner.

 

 

 

 

 

 

^GLH

Syntax:

 

 

Change the

"'^GLH-<vt addr range>,<bargraph hi>'"

bargraph upper

Variable:

 

 

limit.

 

 

variable text address range = 1 - 4000.

 

 

bargraph limit range = 1 - 65535 (bargraph upper limit range).

 

Example:

 

 

 

SEND_COMMAND Panel,"'^GLH-500,1000'"

 

Changes the bargraph upper limit to 1000.

 

 

 

 

 

 

^GLL

Syntax:

 

 

Change the

"'^GLL-<vt addr range>,<bargraph low>'"

bargraph lower

Variable:

 

 

limit.

 

 

variable text address range = 1 - 4000.

 

 

bargraph limit range = 1 - 65535 (bargraph lower limit range).

 

Example:

 

 

 

SEND_COMMAND Panel,"'^GLL-500,150'"

 

Changes the bargraph lower limit to 150.

 

 

 

 

 

 

^GRD

Syntax:

 

 

Change the

"'^GRD-<vt addr range>,<bargraph ramp down time>'"

bargraph

Variable:

 

 

ramp-down time

 

 

variable text address range = 1 - 4000.

in 1/10th of a

bargraph ramp down time = In 1/10th of a second intervals.

second.

 

Example:

 

 

 

SEND_COMMAND Panel,"'^GRD-500,200'"

 

Changes the bargraph ramp down time to 20 seconds.

 

 

 

 

 

 

^GRU

Syntax:

 

 

Change the

"'^GRU-<vt addr range>,<bargraph ramp up time>'"

bargraph

Variable:

 

 

ramp-up time in

 

 

variable text address range = 1 - 4000.

1/10th of a

bargraph ramp up time = In 1/10th of a second intervals.

second.

 

Example:

 

 

 

SEND_COMMAND Panel,"'^GRU-500,100'"

 

Changes the bargraph ramp up time to 10 seconds.

 

 

 

 

 

 