Troubleshooting

Troubleshooting Information (Cont.)

Symptom

Solution

 

 

My Modero panel can’t obtain a

In requesting a DHCP Address, the DHCP Server can take up to a few

DHCP Address

minutes to provide the address.

 

• Verify that an active Ethernet connection is attached to the rear of the

 

Modero before beginning these procedures.

 

• Select Diagnostics > Network Address from the Main menu and

 

verify the System number.

 

• If the IP Address field is still empty, give the Modero a few minutes to

 

negotiate a DHCP Address and try again.

 

 

My panel is not showing up in the

If a Virtual Master has already connected to the target panel, the G4

Virtual Master’s System list of

device retains the information of the previous Virtual Master System

connected devices.

number.

 

• Reboot the panel without plugging the USB cable into the panel.

 

• Configure NetLinx Studio for a Virtual Master connection. Note the

 

System Number used in the Edit Settings window.

 

• Stop communication on the Virtual Master by going to

 

Settings > Stop Communications.

 

• Click Yes to stop communication.

 

• Select the System Number (from the Online Tree tab) and use a right

 

mouse click to select Refresh System. This re-establishes

 

communication with the Virtual Master.

 

Plug-in the mini-USB cable into the corresponding port on the panel.

 

• Wait a few seconds and refresh the system. This re-establishes

 

communication with the Virtual Master. The panel should now appear

 

in the list of available devices.

 

 

My Connection Status button isn’t

"USB Connecting" is displayed when the panel tries to establish USB

blinking and it says the USB is

communication with the PC, either within the NetLinx Studio or

connecting.

TPDesign4 applications.

 

• Remove the USB connector from the panel and close any AMX

 

applications.

 

• Reboot the panel.

 

• Launch the AMX application and attempt reconnect to the panel.

 

• If using Studio for Virtual Master communication, establish a Virtual

 

Master connection, verify the correct System number, stop

 

communication with the Virtual Master, and then re-establish

 

communication by refreshing the system.

 

• After the panel powers-up, reconnect the USB connector to the

 

panel.

 

• Verify that you have a valid USB connection from within your System

 

Tray.

 

 

My on-screen mouse cursor

• The USB connections are not detected until after the particular USB

doesn’t appear.

connection plugged into the corresponding port on the panel and

 

power is cycled to the panel.

 

 

Calibration is not working.

• After the Modero touch panel has been updated with a new firmware

 

kit (downloaded to the panel through NetLinx Studio), the calibration

 

could need to be reset.

 

• Cycling power to the panel should provide a baseline calibration for

 

the particular touch panel. Proceed to the Calibration page and reset

 

the on-screen calibration.

 

 