Telnet Commands

These Telnet Commands are used in NetLinx Studio and are case insensitive.

Telnet Commands

set motion beep

This will enable/disable the button beep sound when the motion sensor detects a motion

Enables/disables

level that rises above the threshold set by the user. It is intended to be used as an aid

during motion testing.

button beep

 

 

sound.

 

 

 

 

show sensors

This command is similar to the batt mon command in operation, except that it displays

Displays realtime

realtime data related to the Motion and Light sensors. Sensor data is displayed as

scrolling text at the rate of 200 ms (default). The loop interval is optional and is in units of

data from motion

"100 milliseconds", e.g., interval = 2 results in a loop interval of 200 ms (5 hz). See table

and light sensors.

below for an example of the output. The following is a description of data items that are

 

 

displayed:

 

Motion - level: The level of motion detected by the sensor.

 

Motion - threshold: The threshold set by the user for activating the Channel.

 

Light

- lux: The amount of lux observed by the light sensor.

 

Light

- avg: The average logarithmic value of lux (avg log(lux)).

 

Light

- BL lvl: The current backlight level (brightness).

 

Light - BL abs: The backlight level determined by the auto-brightness feature (absolute).

 

This value is a measure of the light sensor calibration. At full brightness (when "BL lvl" =

 

100), this value should also equal 100.

 

Light

- threshold: The light threshold set by the user. When "BL lvl" falls below the

 

threshold the channel is activated with a "push" or "on". Above threshold is "release" or

 

"off".

 

 

 

cal light

This command will initiate a light sensor calibration routine. This routine takes 30 seconds

Initiates light

to complete. There is currently no indication that the command is complete. During this

routine, the firmware will record the maximum light value detected and use this value as

sensor calibration

the normal light level in which the panel will be operating. This will enable the panel's

routine.

"auto-brightness" feature to operate correctly.

 

 

Be sure to move away from the front of the panel during the light calibration to allow the

 

light sensor to "see" maximum brightness. Also, the panel should be positioned (installed)

 

and operating in the expected light conditions that the panel will be expected to be used.

 

 

 

88

NXD-500i 5" Wall/Flush Mount Touch Panel with Intercom

Page 94
Image 94
AMX NXD-500i manual Telnet Commands