These commands are used to transmit and receive IR signals from the panel. Each panel has up to 4 transmit ports specifically defined as IR output ports. These ports are AMX 38K, AMX 455K, User 1, and User 2.

^IRM allows the command itself to specify the port number. IRM is needed because commands programmed on the panel itself can only be sent to a single port number . ^IRS is needed to enable the received AMX 38K or 455k. In some cases, both of these ports cannot be enabled at the same time.

Panel IR Commands

^IRM

Pulses the given channel IR on for onTime tenths of seconds. Delays offTime tenths of

Pulses the given

seconds before the next IR pulse is allowed. The port for the IR is given in the command

itself.

channel IR

Syntax:

 

 

SEND_COMMAND <DEV>,"'^IRM-<port>,<channel>,<onTime>,<offTime>'"

 

Variables:

 

None.

 

Example:

 

SEND_COMMAND TP1,"'^IRM-<port>,<channel>,<onTime>,<offTime>'"

 

SEND_COMMAND TP2,"'^IRM-<port>,<channel>,<onTime>,<offTime>'"

 

Specifies the port number to be used.

 

 

^IRS

Enables the received AMX 38K or 455K. The RX Ir port is given in the command itself.

Enable the

Syntax:

received AMX

SEND_COMMAND <DEV>,"'^IRS-<port>'"

38K or 455K

Variables:

 

 

None.

 

Example:

 

SEND_COMMAND <DEV>,"'^IRS-<port>'"

 

 