Sensor Setup

Setup Pages and Descriptions

Sensor Setup

The Sensor Setup page (FIG. 51) allows adjustment of the Light and Motion Sensor parameters on a Modero touch panel.

FIG. 51 Sensor Setup page

The elements of the Sensor Setup page are described in the table below:

Sensor Setup Page Elements

Back:

Saves the changes and returns you to the previously active touch panel page.

 

 

Connection Status icon:

This visual display of the connection status allows the user to have a current

 

visual update of the panel’s connection status regardless of the page that is

 

currently active.

 

• A Lock only appears on the icon if the panel has established a connection

 

with a currently secured target Master requiring a username and password.

 

 

Light:

The Light bargraph displays a vertical bargraph indicating the light level

 

detected by the on-board photo-sensor.

 

 

Light Sensor:

Allows the user to review the Modero panel light sensor port and channel

 

settings:

 

• The Sensor Level field indicates the level used to report the light sensor level

 

back to the NetLinx Master (set in TPD4) (read-only).

 

• The Sensor Level Port field indicates the port used to report the light sensor

 

level back to the NetLinx Master (set in TPD4) (read-only).

 

• The Sensor Channel field indicates the level used to report the sensor

 

channel back to the NetLinx Master (set in TPD4). It is On when below the

 

Light Sensor threshold level (read-only).

 

• The Sensor Channel Port field indicates the port used to report the sensor

 

channel back to the NetLinx Master (set in TPD4) (read-only).

 

 

Motion Sensor:

Provides the following fields:

 

• The Motion Detection field displays a reactive button that changes color

 

(illuminates) when motion is detected by the Modero panel’s front motion

 

sensor.

 

• The Motion Sensor Port field indicates the port used to report the motion

 

sensor channel back to the NetLinx Master (set in TPD4) (read-only).

 

• The Motion Sensor Channel field indicates the channel used to report the

 

motion sensor channel back to the NetLinx Master (set in TPD4) (read-only).

 

 

68