While the NXD-500i is designed to fit into pre-existing NXD-CV5 touch panel sites, the actual installation differs from that of the NXD-CV5 is several significant ways. The NXD-500i can be installed either directly into the (optional) CB-TP5i Rough-In Box or another solid surface environment, using either solid surface screws or the included locking tabs for different mounting options. For more information, please refer to the NXD-500i User Manual, available at www.amx.com.

The NXD-500i is contained within a clear outer housing known as the back box (FIG. 4). This back box is removed when installing the device into a wall or into a Rough-In Box. Because of the backbox, the device may be installed into either a pre-wall surface using a CB-TP5i conduit/wallbox, or into a solid surface using the included locking tabs or either solid surface or drywall screws.

10/100 BaseT Ethernet port

Mini-USB programming port

Plastic backbox

Installing the Trim RingManual background Front of device

FIG. 4 NXD-500i - Side view

Make sure to remove the protective plastic cover from the LCD. If the cover is not removed, the panel may not respond properly to touch points on the LCD or allow proper screen calibration.

Installing the Trim Ring

The outer Trim Ring is secured to the Faceplate with plastic latches. The Trim Ring must first be removed to install the touch panel, and is later resecured when installation is complete.

To install the Trim Ring:

1.Place the Button Trim Ring, latch side down, atop the Faceplate.

2.Firmly press down around the Button Trim Ring until all of the latches are securely inserted into their openings on the Faceplate, and the Button Trim Ring is securely fastened. Verify that the Button Trim Ring is firmly inserted onto the Faceplate and that no gaps remain between this Trim Ring and the outer surface of the Faceplate.

3.Place the Faceplate back onto the device. Make sure to align the Microphone, Light, and PIR Motion sensor locations on the main unit to their respective openings on the Faceplate assembly.