System Information

SPECTRA IV

LANGUAGE

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS>

ACK ALERT*

RESET CAMERA

CYCLE CAMERA POWER REBOOT SYSTEM

EXIT

SYSTEM INFORMATION

SERIAL #

DOME DRIVE MODEL

BACK BOX MEMORY

SOFTWARE VERSION

BUILD

FONT VERSION

COMM

DADDRESS P ADDRESS CM9500 MODE 32 PRESETS PROTOCOL PRESSURIZED* <ADDITIONAL>

BACK

EXIT

ADDITIONAL

FREE MEMORY LAST RESET AZIMUTH ZERO OFFSET MOTOR ACTIVE CAMERA ACTIVE VIDEO LEVEL CAMERA MODEL LANGUAGE 1 LANGUAGE 2 LANGUAGE 3 LANGUAGE 4 LANGUAGE 5 LANGUAGE 6 LANGUAGE 7 LANGUAGE 8 LANGUAGE 9 LANGUAGE 10 <DIPSWITCH INFORMATION>

BACK

EXIT

The System Information menu displays the dome drive model, software version, available memory, DIP switch information, and other diagnostic information.

System settings cannot be changed using this menu; this information is for reference only.

Use the following steps to display the System Information menu:

1.Use the joystick to position the cursor beside SYSTEM INFORMATION.

2.Press Iris Open. The SYSTEM INFORMATION menu opens.

DIP SWITCH INFORMATION

The DIP Switch Information menu displays the dome drive’s current DIP switch settings. This provides a way to remotely view the DIP switch settings without removing the dome drive from the back box.

DIP SWITCH INFORMATION

 

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8 9 0

]

SW1[- - - - - - - -

]

SW2[- - - - - - - - - -

SW1 1-8 :

D ADDRESS 1

P ADDRESS 1

SW2 1 : 32 PRESETS. OFF

SW2 2 : CM9500 MODE. OFF

SW2 3 : COAX SPIV

SW2 4-5 : RS422 <->

SW2 6-8 : COMM. 2400.N.8.1

SW2 9 : UTC SOURCE. COAX

SW2 10 : TX/RX TERM.. OFF

PRESS IRIS OPEN TO CONTINUE

* This setting applies only to Pressurized Spectra IV dome systems.

C3412M-D (12/08)

35

Image 35
Contents Spectra IV and Spectra IV SE Series Page Contents Field Align Wide Dynamic RangeRepeat Ack Action Activate Aux Current Reading Reset Alert Welcome SW2 Switch 2 CM9502 Setting InstallationSwitch Settings SW2 Switch 1 AD-32 Preset SystemSW2 Switches 4-5 Serial Port Settings SW2 Switch 3 Control System CompatibilitySW2 Switches 6-8 Baud Settings Dome Drive InstallationTable A. Switch Settings for SW1 P-Type Control OFF Table B. Switch Settings for SW1 D-Type ControlTable B. Switch Settings for SW1 D-Type Control 100 106 141 176 211 246 Getting Started Operation How to Operate Your Dome SystemQuick Programming Guide Accessing Main Menu PresetCM9500 VCD5000 Endura Workstation16X LowLight Color Menu Tree AUX Dome SettingsLine Sync Presets Edit the Password Clock Event18X LowLight Day/Night Menu Tree Title Text Line Sync Presets PatternsAlarms AUX Edit the Password Clock22X EXview LowLight Color Menu Tree Line Sync Alarms Alarm Settings23X LowLight Day/Night Menu Tree Edit Detection Areas Patterns 35X LowLight Day/Night Menu Tree Edit Detection Areas Exit ACK Alert Reset CameraLanguage Spectra LanguageSystem Information DIP Switch InformationDIP Switch Information Address SW2 1 32 PRESETS. OFFRestore Factory Defaults Back Exit Display SetupExit Display Setup Preset Label XXX.XX Title Text Save and Exit Cancel and Exit HelpType of Lighting Dome SettingsExit Dome Settings Camera CameraBack Exit Camera Advanced Settings Back ExitZoom Limit LOW Light Limit Zoom SpeedApplies only to 18X, 23X, and 35X models IR CUT FilterAGC Limit Advanced Camera SettingsShutter Speed Back Exit Auto IrisAuto White Balance Gain B Gain Auto White Balance Auto SharpnessAuto Iris Level Auto Iris Peak Dome Settings ACK Alert Reset CameraBacklight Compensation BLC Video LevelField Align Sensor Scan ModeElectronic Image Stabilization LOW LUX Noise Reduction Image EnhancementApplies only to 23X and 35X models Wide Dynamic RangeProportional PAN Auto FlipBack Exit Motion Exit Dome Settings Camera Motion Power UPPark Time Scan Speed Preset Freeze FrameLimit Stops Azimuth Zero Back Exit Power UP Power UP Action Power UPPower UP Action Line Sync Back Exit Line Sync Line Sync PhaseModel Number of Stored Presets PresetsAbcdefghij Cancel Klmnopqrst Uvwxyz Space Back Exit Presets Preset NumberLabel for Preset Preset Number C3412M-D 12/08 Edit Detection Areas Enable Motion DetectionPresets Preset Number Preset not Defined Edit Schedule Clear Preset Clear Camera Settings Back ExitMotion Detection Areas Edit Schedule Activate AUX CommandAUX Time Back Exit Patterns PatternsPatterns Zones Zones SET Windows Back Exit Window BlankingBack Exit Window Blanking StyleClear Window Enable Window Reverse Clear Window Back ExitReverse Window Blank Tilt Angles Blank ALL ABOVE/BLANK ALL belowAlarms C3412M-D 12/08 Default Normally open Dwell Time Secs Edit Schedule Back Exit Back Exit AUX AUX 1 Mode Toggle Dwell Time Secs AUX 2 ModeAUX Edit Title Text Title TextBack Exit Title Text Repeat AlertCurrent Reading Reset AlertACK Action Activate AUXClear Back Exit Edit the Password PasswordBack Exit Password Clock END Date Month October DAY END Time Clock Time Base Internal ClockHour Month April DAYEND Date Month October Week Last DAY Sunday END Time Time Base Internal ClockMM/DD/YYYY Month April Week 1ST DAY SundayEvent Back Exit Reference Information Event TypeBack Exit Event Event Type Event Label HolidayEdit Event Label Event LabelEdit Event Event Label Event Active Event Time Event Type Preset Number Back ExitEdit Event Back Exit Event Event Type Event Label Edit Event LabelHoliday Clear EventList Event Month January DAY Back Exit Edit HolidayEdit Holiday Occurrence List Holidays Clear HolidayEvent Number Event Type Label Time Occurs Holiday Scheduled EventsReboot System Reset, Cycle Power, RebootReset Camera Cycle Camera PowerSoftware/Language File Upload Suggested Preventative Maintenance 16X Models SpecificationsDD4CBW18 18X ModelsDD4C22 22X ModelsDD4CBW23 23X ModelsDD4CBW23-X DD4CBW35 35X ModelsDD4CBW35-X Page Product Warranty and Return Information