SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
EXIT
DOME SETTINGS
<CAMERA>
<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>
<WINDOW BLANKING> <ALARMS>
<AUX>
<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD> <CLOCK> <EVENT>
BACK
EXIT
PRESETS
PRESET NUMBER
* * * PRESET NOT DEFINED * * *
<EDIT PRESET LABEL> <EDIT PRESET SCENE> <EDIT CAMERA SETTINGS> <MOTION DETECTION>
<EDIT SCHEDULE>
<CLEAR PRESET>
<CLEAR CAMERA SETTINGS>
BACK
EXIT
REFERENCE INFORMATION AZIMUTH
ELEVATION
ZOOM RATIO
CUSTOM CAMERA SETTINGS
MOTION DETECTION
MOTION DETECTION ENABLED <EDIT DETECTION AREAS> ACTIVATE AUX
AUX TIME (SECS)
BACK
EXIT
ENABLE MOTION DETECTION
(Applies only to 23X and 35X models.)
The following are the settings for motion detection:
OFF (default): Motion detection is turned off (disabled).
ON: Motion detection is turned on (enabled).
Note: Motion detection does not work if the shutter speed is set at less than 1/60 of a second.
EDIT DETECTION AREAS
(Applies only to 23X and 35X models.)
Four motion detection areas can be defined for a preset. Use the following steps to edit motion detection areas.
1.Edit detection areas 1, 2, 3, or 4:
a.Use the joystick to position the cursor beside EDIT DETECTION AREAS.
b.Press Iris Open. The EDIT DETECTION AREAS programming window appears on the monitor.
c.Use the joystick to position the cursor beside LOCATION for DETECTION AREA 1, 2, 3, or 4.
d.Press Iris Open. The cursor moves to the right next to the number 0.
e.Move the joystick up. A blue rectangle appears in the upper
f.Use the joystick to place the blue rectangle over the desired detection area.
g.Press Iris Open to make a selection.
2.Set the sensitivity of the motion detection area:
a.Position the cursor next to SENSITIVITY for DETECTION AREA 1, 2, 3, or 4.
b.Press Iris Open, the cursor moves to the right.
c.Use the joystick to select one of the following sensitivity levels:
HIGH: The sensitivity level is high.
MEDIUM (default): Average sensitivity.
LOW: The sensitivity level is low.
d.Press Iris Open to make selection.
* This setting applies only to Pressurized Spectra IV dome systems.
60 |