Pelco C3412M-D manual Edit Holiday Occurrence, Month January DAY Back Exit

Page 85

SPECTRA IV

LANGUAGE

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS>

ACK ALERT*

RESET CAMERA

CYCLE CAMERA POWER REBOOT SYSTEM

EXIT

DOME SETTINGS

<CAMERA>

<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>

<WINDOW BLANKING> <ALARMS>

<AUX>

<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD> <CLOCK> <EVENT>

BACK

EXIT

EVENT

EVENT TYPE

EVENT LABEL

<EDIT EVENT LABEL> <EDIT EVENT> <CLEAR EVENT> <LIST EVENT>

HOLIDAY

<EDIT HOLIDAY> <CLEAR HOLIDAY> <LIST HOLIDAYS>

BACK

EXIT

REFERENCE INFORMATION

EDIT HOLIDAY

Use the following steps to edit a holiday:

1.Use the joystick to position the cursor beside EDIT EVENT LABEL.

2.Press Iris Open.

3.Use the joystick to position the cursor beside OCCURRENCE. Press Iris Open. The following are the settings for Occurrence:

FIXED DATE: The holiday occurs on the same date each year.

RELATIVE DATE: The holiday occurs on a different date each year, such as the third Sunday in April.

4.If FIXED DATE was selected as the occurrence, the following appears on the monitor:

EDIT HOLIDAY

OCCURRENCE

FIXED DATE

MONTH

JANUARY

DAY

1

BACK

 

EXIT

 

a.Use the joystick to position the cursor beside MONTH. Press Iris Open. Scroll through the options until the desired month appears. Press Iris Open to select the month.

b.Use the joystick to position the cursor beside DAY. Press Iris Open. Scroll through the options until the desired date appears. Press Iris Open to select the day.

5.If RELATIVE DATE was selected as the occurrence, the following appears on the monitor:

a.Use the joystick to position the cursor beside MONTH. Press Iris Open. Scroll through the options until the desired month appears. Press Iris Open to select the month.

b.Use the joystick to position the cursor beside WEEK. Press Iris Open. Scroll through the options until the desired week appears. Press Iris Open to select the week.

c.Use the joystick to position the cursor beside DAY. Press Iris Open. Scroll through the options until the desired day of the week appears. Press Iris Open to select the day.

* This setting applies only to Pressurized Spectra IV dome systems.

C3412M-D (12/08)

85

Image 85
Contents Spectra IV and Spectra IV SE Series Page Contents Field Align Wide Dynamic RangeRepeat Ack Action Activate Aux Current Reading Reset Alert Welcome Switch Settings InstallationSW2 Switch 1 AD-32 Preset System SW2 Switch 2 CM9502 SettingSW2 Switches 4-5 Serial Port Settings SW2 Switch 3 Control System CompatibilitySW2 Switches 6-8 Baud Settings Dome Drive InstallationTable A. Switch Settings for SW1 P-Type Control OFF Table B. Switch Settings for SW1 D-Type ControlTable B. Switch Settings for SW1 D-Type Control 100 106 141 176 211 246 Getting Started Operation How to Operate Your Dome SystemQuick Programming Guide Accessing Main Menu PresetCM9500 VCD5000 Endura Workstation16X LowLight Color Menu Tree Line Sync Presets Dome SettingsEdit the Password Clock Event AUX18X LowLight Day/Night Menu Tree Alarms AUX Line Sync Presets PatternsEdit the Password Clock Title Text22X EXview LowLight Color Menu Tree Line Sync Alarms Alarm Settings23X LowLight Day/Night Menu Tree Edit Detection Areas Patterns 35X LowLight Day/Night Menu Tree Edit Detection Areas Language ACK Alert Reset CameraSpectra Language ExitDIP Switch Information DIP Switch InformationAddress SW2 1 32 PRESETS. OFF System InformationExit Display Setup Preset Label Display SetupRestore Factory Defaults Back Exit XXX.XX Title Text Save and Exit Cancel and Exit HelpExit Dome Settings Camera Dome SettingsCamera Type of LightingZoom Limit Advanced Settings Back ExitBack Exit Camera LOW Light Limit Zoom SpeedApplies only to 18X, 23X, and 35X models IR CUT FilterShutter Speed Advanced Camera SettingsAGC Limit Auto White Balance Gain B Gain Auto IrisBack Exit Auto White Balance Auto SharpnessBacklight Compensation BLC Dome Settings ACK Alert Reset CameraVideo Level Auto Iris Level Auto Iris PeakField Align Sensor Scan ModeElectronic Image Stabilization LOW LUX Noise Reduction Image EnhancementApplies only to 23X and 35X models Wide Dynamic RangeProportional PAN Auto FlipPark Time Exit Dome Settings Camera Motion Power UPBack Exit Motion Scan Speed Preset Freeze FrameLimit Stops Azimuth Zero Power UP Action Power UPBack Exit Power UP Power UP Action Line Sync Back Exit Line Sync Line Sync PhaseModel Number of Stored Presets PresetsLabel for Preset Preset Number Back Exit Presets Preset NumberAbcdefghij Cancel Klmnopqrst Uvwxyz Space C3412M-D 12/08 Presets Preset Number Preset not Defined Enable Motion DetectionEdit Schedule Clear Preset Clear Camera Settings Back Exit Edit Detection AreasMotion Detection Areas AUX Time Activate AUX CommandEdit Schedule Patterns Zones PatternsBack Exit Patterns Zones Back Exit Window Blanking Window BlankingStyle SET Windows Back ExitReverse Enable Window Reverse Clear Window Back ExitClear Window Window Blank Tilt Angles Blank ALL ABOVE/BLANK ALL belowAlarms C3412M-D 12/08 Default Normally open AUX Back Exit AUX AUX 1 Mode Toggle Dwell Time Secs AUX 2 ModeDwell Time Secs Edit Schedule Back Exit Back Exit Title Text Title TextEdit Title Text Repeat AlertACK Action Reset AlertActivate AUX Current ReadingClear Back Exit Password PasswordBack Exit Edit the Password Clock Hour Clock Time Base Internal ClockMonth April DAY END Date Month October DAY END TimeMM/DD/YYYY Time Base Internal ClockMonth April Week 1ST DAY Sunday END Date Month October Week Last DAY Sunday END TimeEvent Back Exit Event Event Type Event Label Event TypeHoliday Back Exit Reference InformationEdit Event Label Event LabelEdit Event Event Type Preset Number Back ExitBack Exit Event Event Type Event Label Edit Event Label Edit Event Event Label Event Active Event TimeList Event Clear EventHoliday Edit Holiday Occurrence Edit HolidayMonth January DAY Back Exit List Holidays Clear HolidayEvent Number Event Type Label Time Occurs Holiday Scheduled EventsReset Camera Reset, Cycle Power, RebootCycle Camera Power Reboot SystemSoftware/Language File Upload Suggested Preventative Maintenance 16X Models SpecificationsDD4CBW18 18X ModelsDD4C22 22X ModelsDD4CBW23 23X ModelsDD4CBW23-X DD4CBW35 35X ModelsDD4CBW35-X Page Product Warranty and Return Information