SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER REBOOT SYSTEM
EXIT
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC> <PRESETS> <PATTERNS> <ZONES>
<WINDOW BLANKING> <ALARMS>
<AUX>
<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD> <CLOCK> <EVENT>
BACK
EXIT
MOTION
AUTO FLIP PROPORTIONAL PAN PARK TIME (MINUTES)
PARK ACTION SCAN SPEED (DEG/S) PRESET FREEZE FRAME
LIMIT STOPS
<SET MANUAL STOPS> <CLEAR MANUAL STOPS> <SET SCAN STOPS> <CLEAR SCAN STOPS>
<SET AZIMUTH ZERO> <CLEAR AZIMUTH ZERO>
BACK
EXIT
REFERENCE INFORMATION MANUAL LIMITS SET SCAN LIMITS SET
PARK TIME
This feature allows the dome to begin a specified operation (scan, preset, or pattern) after a programmed time of inactivity.
Park time can be programmed from
Park Action
This feature will define the activity when the dome parks. The following settings are available: NONE (default): No action.
AUTO SCAN: Dome starts auto scan operation.
RANDOM SCAN: Dome starts random scan operation.
FRAME SCAN: Dome starts frame scan operation.
PRESET 1: Dome goes to preset 1.
PRESET 8: Dome goes to preset 8.
PATTERN 1: Dome runs pattern 1.
PATTERN 2: Dome runs pattern 2.
PATTERN 3: Dome runs pattern 3.
PATTERN 4: Dome runs pattern 4.
PATTERN 5: Dome runs pattern 5.
PATTERN 6: Dome runs pattern 6.
PATTERN 7: Dome runs pattern 7.
PATTERN 8: Dome runs pattern 8.
(Only 22X, 23X, and 35X models allow PATTERN 2 through PATTERN 8.)
* This setting applies only to Pressurized Spectra IV dome systems.
51 |