SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION> <DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER REBOOT SYSTEM
EXIT
DOME SETTINGS
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC> <PRESETS> <PATTERNS> <ZONES>
<WINDOW BLANKING> <ALARMS>
<AUX>
<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD> <CLOCK> <EVENT>
BACK
EXIT
MOTION
AUTO FLIP PROPORTIONAL PAN PARK TIME (MINUTES)
PARK ACTION SCAN SPEED (DEG/S) PRESET FREEZE FRAME
LIMIT STOPS
<SET MANUAL STOPS> <CLEAR MANUAL STOPS> <SET SCAN STOPS> <CLEAR SCAN STOPS>
<SET AZIMUTH ZERO> <CLEAR AZIMUTH ZERO>
BACK
EXIT
REFERENCE INFORMATION MANUAL LIMITS SET SCAN LIMITS SET
AZIMUTH ZERO
Azimuth is the pan angle from zero to 359 degrees. Azimuth zero is the pan position you specify to be the zero degree point. Azimuth zero is normally set to magnetic north. Once set, azimuth and compass readings are based on the set Azimuth Zero point.
To program azimuth zero:
1.Use the joystick to position the cursor beside SET AZIMUTH ZERO.
2.Press Iris Open.
3.Follow the directions displayed on the monitor.
To clear azimuth zero:
1.Use the joystick to position the cursor beside CLEAR AZIMUTH ZERO.
2.Press Iris Open.
3.Follow the directions displayed on the monitor.
* This setting applies only to Pressurized Spectra IV dome systems.
54 |