Pelco C3412M-D manual Exit Display Setup Preset Label, Restore Factory Defaults Back Exit

Page 36

Display Setup

SPECTRA IV

LANGUAGE

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS>

ACK ALERT*

RESET CAMERA

CYCLE CAMERA POWER REBOOT SYSTEM

EXIT

DISPLAY SETUP

PRESET LABEL

ZONE LABEL ZOOM AZIMUTH/ELEVATION DIRECTION ALARM MESSAGE DATE/TIME

EVENT LABEL <LABEL POSITIONS>

RESTORE FACTORY DEFAULTS BACK

EXIT

Display setup allows you to program how labels are displayed on the monitor. The following labels are available:

PRESET LABEL: Identifies preset.

ZONE LABEL: Identifies zone.

ZOOM: Identifies the amount of magnification.

AZIMUTH1/ELEVATION2: Amount of pan from zero degrees vertical and the amount of tilt from zero degrees horizontal.

DIRECTION: Displays compass direction.

ALARM MESSAGE: Displays activated alarm.

DATE/TIME: Displays current date and time.

EVENT LABEL: Displays activated event.

A preset label is displayed when a preset is called. A zone label is displayed when the system moves into a zone. The zoom ratio label is displayed when zoom is activated. Azimuth/elevation and direction labels are displayed when pan/tilt is activated. An alarm message appears on the monitor when an alarm occurs. An event label appears on the monitor when an event occurs.

The following settings are available for each label except date and time:

OFF: Label is not displayed when activated.

CONSTANT: The label is continually displayed when activated.

2 SECONDS: The label is displayed for 2 seconds after activation.

5 SECONDS: The label is displayed for 5 seconds after activation.

10 SECONDS: The label is displayed for 10 seconds after activation.

The settings for date and time are ON or OFF.

1Azimuth is the pan angle from zero to 359 degrees.

2Elevation is the tilt position from zero (horizon) to -90 degrees.

* This setting applies only to Pressurized Spectra IV dome systems.

36

C3412M-D (12/08)

Image 36
Contents Spectra IV and Spectra IV SE Series Page Contents Wide Dynamic Range Field AlignRepeat Ack Action Activate Aux Current Reading Reset Alert Welcome Installation Switch SettingsSW2 Switch 1 AD-32 Preset System SW2 Switch 2 CM9502 SettingSW2 Switch 3 Control System Compatibility SW2 Switches 4-5 Serial Port SettingsDome Drive Installation SW2 Switches 6-8 Baud SettingsTable A. Switch Settings for SW1 P-Type Control Table B. Switch Settings for SW1 D-Type Control OFFTable B. Switch Settings for SW1 D-Type Control 100 106 141 176 211 246 Getting Started How to Operate Your Dome System OperationAccessing Main Menu Preset Quick Programming GuideCM9500 Endura Workstation VCD500016X LowLight Color Menu Tree Dome Settings Line Sync PresetsEdit the Password Clock Event AUX18X LowLight Day/Night Menu Tree Line Sync Presets Patterns Alarms AUXEdit the Password Clock Title Text22X EXview LowLight Color Menu Tree Alarms Alarm Settings Line Sync23X LowLight Day/Night Menu Tree Edit Detection Areas Patterns 35X LowLight Day/Night Menu Tree Edit Detection Areas ACK Alert Reset Camera LanguageSpectra Language ExitDIP Switch Information DIP Switch InformationAddress SW2 1 32 PRESETS. OFF System InformationDisplay Setup Exit Display Setup Preset LabelRestore Factory Defaults Back Exit Title Text Save and Exit Cancel and Exit Help XXX.XXDome Settings Exit Dome Settings CameraCamera Type of LightingAdvanced Settings Back Exit Zoom LimitBack Exit Camera Zoom Speed LOW Light LimitIR CUT Filter Applies only to 18X, 23X, and 35X modelsAdvanced Camera Settings Shutter SpeedAGC Limit Auto Iris Auto White Balance Gain B GainBack Exit Auto Sharpness Auto White BalanceDome Settings ACK Alert Reset Camera Backlight Compensation BLCVideo Level Auto Iris Level Auto Iris PeakSensor Scan Mode Field AlignElectronic Image Stabilization Image Enhancement LOW LUX Noise ReductionWide Dynamic Range Applies only to 23X and 35X modelsAuto Flip Proportional PANExit Dome Settings Camera Motion Power UP Park TimeBack Exit Motion Preset Freeze Frame Scan SpeedLimit Stops Azimuth Zero Power UP Power UP ActionBack Exit Power UP Power UP Action Back Exit Line Sync Line Sync Phase Line SyncPresets Model Number of Stored PresetsBack Exit Presets Preset Number Label for Preset Preset NumberAbcdefghij Cancel Klmnopqrst Uvwxyz Space C3412M-D 12/08 Enable Motion Detection Presets Preset Number Preset not DefinedEdit Schedule Clear Preset Clear Camera Settings Back Exit Edit Detection AreasMotion Detection Areas Activate AUX Command AUX TimeEdit Schedule Patterns Patterns ZonesBack Exit Patterns Zones Window Blanking Back Exit Window BlankingStyle SET Windows Back ExitEnable Window Reverse Clear Window Back Exit ReverseClear Window Blank ALL ABOVE/BLANK ALL below Window Blank Tilt AnglesAlarms C3412M-D 12/08 Default Normally open Back Exit AUX AUX 1 Mode Toggle Dwell Time Secs AUX 2 Mode AUXDwell Time Secs Edit Schedule Back Exit Title Text Back Exit Title TextEdit Title Text Alert RepeatReset Alert ACK ActionActivate AUX Current ReadingClear Password Back Exit PasswordBack Exit Edit the Password Clock Clock Time Base Internal Clock HourMonth April DAY END Date Month October DAY END TimeTime Base Internal Clock MM/DD/YYYYMonth April Week 1ST DAY Sunday END Date Month October Week Last DAY Sunday END TimeEvent Event Type Back Exit Event Event Type Event LabelHoliday Back Exit Reference InformationEvent Label Edit Event LabelEvent Type Preset Number Back Exit Edit EventBack Exit Event Event Type Event Label Edit Event Label Edit Event Event Label Event Active Event TimeClear Event List EventHoliday Edit Holiday Edit Holiday OccurrenceMonth January DAY Back Exit Clear Holiday List HolidaysScheduled Events Event Number Event Type Label Time Occurs HolidayReset, Cycle Power, Reboot Reset CameraCycle Camera Power Reboot SystemSoftware/Language File Upload Suggested Preventative Maintenance Specifications 16X Models18X Models DD4CBW1822X Models DD4C2223X Models DD4CBW23DD4CBW23-X 35X Models DD4CBW35DD4CBW35-X Page Product Warranty and Return Information