WINDOW BLANKING
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER REBOOT SYSTEM
EXIT
DOME SETTINGS
<CAMERA>
<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>
<WINDOW BLANKING> <ALARMS>
<AUX>
<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD> <CLOCK> <EVENT>
BACK
EXIT
WINDOW BLANKING
Window blanking allows a user to program
The 16X and 18X models have one
Spectra IV and Spectra IV SE dome systems have two styles of window blanking: Gray and Smear. If the style is set to Gray, the blanked area is covered with a solid gray window. If Smear is selected images behind the window will be noticeable but not distinguishable.
To set a window blanking area:
1.Use the joystick to position the cursor beside WINDOW BLANKING. Press Iris Open. The WINDOW BLANKING menu appears on the screen.
2.Move the joystick to position the cursor beside SET WINDOWS. Press Iris Open to enter.
3.Position the cursor beside WINDOW NUMBER. Press Iris Open. The cursor moves to the right.
4.Move the joystick up or down to view selections. Press Iris Open to enter selection.
5.Use the joystick to position the cursor beside EDIT WINDOW LOCATION. Press Iris Open, and then follow the instructions that appear on the screen. When all four corners are set, the SET WINDOWS menu reappears, the blanked area is displayed, and the ENABLE WINDOW option is set to YES.
Notes:
STYLE
BLANK ALL ABOVE BLANK ALL BELOW
<SET WINDOWS>
BACK
EXIT
•Use the inside corner of the window selection tool as a guide when selecting the upper left, upper right, bottom right, and bottom left corners of the window.
•Set windows are not visible when editing a new window location.
INSIDE CORNER |
SET WINDOWS |
|
WINDOW NUMBER |
|
<EDIT WINDOW LOCATION> |
|
<EDIT WINDOW ZOOM> |
|
<EDIT SCHEDULE> |
|
ENABLE WINDOW |
|
REVERSE |
|
CLEAR WINDOW |
|
BACK |
|
EXIT | * This setting applies only to Pressurized Spectra IV dome systems. |
| 65 |