SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER REBOOT SYSTEM
EXIT
DOME SETTINGS
<CAMERA>
<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>
<WINDOW BLANKING> <ALARMS>
<AUX>
<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD> <CLOCK> <EVENT>
BACK
EXIT
ALARMS
RESUME
SEQUENCE (SECS)
RESET DELAY (SECS)
<ALARM SETTINGS>
BACK
EXIT
ALARM SETTINGS
ALARM NUMBER
ALARM PRIORITY ALARM ACTION ACTIVATE AUX ALARM CONTACT <EDIT SCHEDULE>
BACK
EXIT
3.Select the alarm priority:
a.Use the joystick to position the cursor beside ALARM PRIORITY.
b.Press Iris Open. The cursor moves to the right.
c.Move the joystick up or down to view the available selections. Available settings include HIGH, MEDIUM, and LOW (default). If multiple alarms with different priorities are active at the same time, the dome will only go to the alarms with the highest priority.
d.Press Iris Open to enter selection.
HIGH: Alarm action takes highest priority and will override manual PTZ control.
MEDIUM/LOW: Alarm action will not occur if an alarm occurs during manual pan, tilt, and zoom control.
4.Set the alarm action:
a.Use the joystick to position the cursor beside ALARM ACTION.
b.Press Iris Open. The cursor moves to the right.
c.Move the joystick up or down to view the available selections. The following are the settings for alarm action:
NONE: No action when alarm is triggered.
PRESET: Dome goes to the preset that is the same as the alarm number. Preset 1 will go to Alarm 1.
PATTERN 1: Dome runs pattern 1 when alarm is triggered.
PATTERN 2: Dome runs pattern 2 when alarm is triggered.
PATTERN 3: Dome runs pattern 3 when alarm is triggered.
PATTERN 4: Dome runs pattern 4 when alarm is triggered.
PATTERN 5: Dome runs pattern 5 when alarm is triggered.
PATTERN 6: Dome runs pattern 6 when alarm is triggered.
PATTERN 7: Dome runs pattern 7 when alarm is triggered.
PATTERN 8: Dome runs pattern 8 when alarm is triggered.
AUTO SCAN: Dome starts auto scan operation when alarm is triggered.
RANDOM SCAN: Dome starts random scan operation when alarm is triggered.
FRAME SCAN: Dome starts frame scan operation when alarm is triggered.
d.Press Iris Open to enter selection.
* This setting applies only to Pressurized Spectra IV dome systems.
| 69 |