3.3.2Exposure Timing with the Positive Polarity Trigger Signal
Input Trigger signal 
Trigger signal
(With Photocoupler delay
![]()
![]()
Filtering *Note.1
Less than 30 CLK 5useconds
T1'
Exposure time
SUB
75 CLK
Exposure tim: T1' = Preset exposure time
SG
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 30 CLK. Please input a trigger signal with more than 31 CLK pulse width.
Note 2: The exposure will start 105 CLK after the rising edge of the trigger signal.
3.3.3Exposure Timing with the Negative Polarity Trigger Signal
Input Trigger signal 
Trigger signal
(With Photocoupler delay
![]()
![]()
Filtering *Note.1
Less than 30 CLK 60 useconds
T1'
Exposure time
SUB
75 CLK
Exposure tim: T1' = Preset exposure time
SG
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 30 CLK. Please input a trigger signal with more than 31 CLK pulse width.
Note 2: The exposure will start 105 CLK after the rising edge of the trigger signal.