3.2.2Exposure Timing with the Positive Polarity Trigger Signal
Input Trigger signal |
|
|
|
|
|
|
|
|
|
|
|
|
| (127 CLK) |
|
| |||
|
|
|
| T1 |
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
Trigger signal |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
(With Photocoupler delay |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| T1 |
|
|
|
|
|
|
|
|
| ||
| Less than |
| Filtering *Note.1 |
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
| 5 useconds |
| 30 CLK |
|
|
|
|
|
|
|
|
|
|
T1'
Exposure time
SUB
75 CLK
Exposure time:: T1' = T1 + 127 CLK
SG
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 30 CLK. Please input a trigger signal with more than 31 CLK pulse width.
Note 2: The exposure will start 105 CLK after the rising edge of the trigger signal.
3.2.3Exposure Timing with the Negative Polarity Trigger Signal
Input Trigger signal |
|
|
|
|
| T1 |
|
|
|
|
|
|
| (127 CLK) |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
Trigger signal |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| T1 |
|
|
|
|
|
|
|
|
| ||||
(With Photocoupler delay |
|
| Filtering *Note.1 |
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| 30 CLK |
|
|
|
|
|
|
|
|
|
| ||||||
|
| Less than |
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
| 60 useconds |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
T1'
Exposure time
SUB
75 CLK
Exposure time: T1' = T1 + 127 CLK
SG
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 30 CLK. Please input a trigger signal with more than 31 CLK pulse width.
Note 2: The exposure will start 105 CLK after the rising edge of the trigger signal.
| 12/38 | |
User’s Guide Rev. 1.02 | ||
|