Ricoh FV-G200B1 manual 34/38

Page 34

Command No.

 

 

 

 

 

 

 

 

Command Description

 

50H: [7..0]

 

[Y_offset for AOI]

 

 

 

 

 

 

 

51H: [15..8]

 

Initial data: 0, data range: 2 ≤ “Y_offset + Height” ≤ 1,236

 

 

 

Sets the Y_offset (the vertical start position of the image for the AOI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52H: [7..0]

 

[Height for AOI]

 

 

 

 

 

 

 

53H: [15..8]

 

Initial data: 1,236, data range: 2 ≤ “Y_offset + Height” ≤ 1,236

 

 

 

Sets the height (the vertical size of the image for the AOI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

54H: [7..0]

 

[X_offset for AOI]

 

 

 

 

 

 

 

55H: [15..8]

 

Initial data: 0, data range: 8 ≤ “Y_offset + Height” ≤ 1,624

 

 

 

Sets the X_offset (the horizontal start position of the image for the AOI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

56H: [7..0]

 

[Width for AOI]

 

 

 

 

 

 

 

 

57H: [15..8]

 

Initial data: 1,624, data range: 8 ≤ “Y_offset + Height” ≤ 1,624

 

 

 

Sets the width (the horizontal size of the image for the AOI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60H: [7..0]

 

[Camera mode 1] Initial data: 00H

 

 

 

 

 

 

 

Sets the white balance area ON/OFF and the gamma table ON/OFF.

 

 

 

D[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

D6

 

D5

D4

D3

D2

D1

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7 to D5:

No function

 

 

 

Always set at “000”

 

 

 

D4:

 

 

White balance area ON/OFF

0: OFF (Full screen)

1: ON (setup area)

 

 

D3 to D1:

No function

 

 

 

Always set as “000”

 

 

 

D0:

 

 

Gamma table ON/OFF

 

0: OFF (Gamma=1.0)

1: ON

 

 

 

 

 

 

92H: [7..0]

 

[Iris lens manual adjustment] Initial data: 01H

 

 

 

 

 

Sets the iris lens manual adjustment operation.

 

 

 

 

 

D[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

D6

 

D5

D4

D3

D2

D1

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7 to D2:

No function

 

 

 

Always set as “000000”

 

 

D1 to D0:

Manual adjustment operation

00: Hold

 

 

 

 

 

 

 

 

 

 

 

01: Open

 

 

 

 

 

 

 

 

 

 

 

10: Close

 

 

 

 

 

 

 

 

 

 

 

11: No Function (Prohibited setting. Do not set this value)

 

 

 

 

 

 

 

 

 

 

 

 

 

FV-G200B1

34/38

User’s Guide Rev. 1.02

 

Image 34
Contents GigE Vision VGA Monochrome CCD Camera FV-G200B1 FV-G200B1 User’s Guide RevTable of Contents Connector Specifications RJ45 ConnectorDC Iris Lens Connector Power-I/O ConnectorFV-G200B1 User’s Guide Rev Equivalent Circuit for the Input Pin of the I/O Connector Or equivalent connectorHorizontal Timing Vertical Timing Full Scanning2 1/2 Partial Scanning 3 1/4 Partial ScanningAOI Area of Interest Fval Lval SUBPixel Transferring Image Pulse Width Trigger Mode Normal ModeTiming Trigger signal Exposure Timing with the Positive Polarity Trigger SignalInput Trigger signal Trigger signal With Photocoupler delayEdge Preset Trigger Mode 14/38 15/38 16/38 Reset mode Communication Method Communication SettingsCommunication Format Name Descriptions 【Example Code】Reading the data from the command 00H Camera Control Command Camera Command List Device Code22/38 23/38 24/38 Descriptions of the Camera Control Commands Device code Underline settings are the factory default settings26/38 27/38 28/38 29/38 30/38 Descriptions of the Camera Commands Device code AGC32/38 33/38 34/38 GenICam Command / Camera Command Reference Table GenICam command Device Command Function2EH 37/38 38/38