4.4.3Descriptions of the Camera Control Commands (Device code: 000000);
(The underline settings are the factory default settings)
Command No. |
|
|
|
|
|
|
|
|
|
| Command Description |
| ||||
|
| [camera function mode 1] Initial data: MOD1[7..0] = 89H |
|
| ||||||||||||
10H: |
| Sets the camera function mode. |
|
|
|
|
|
|
|
| ||||||
MOD1[7..0] |
| D[7..0] |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| D7 | D6 | D5 | D4 |
| D3 |
| D2 |
| D1 |
| D0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| D7: |
| No Function |
|
|
|
|
| Always set as “1” |
| |||||
|
| D6: |
| Trigger Polarity |
|
|
| 0: Positive |
| 1: Negative | ||||||
|
| D5: |
| Trigger Mode |
|
|
|
|
| 0: Edge Preset |
| 1: Pulse Width | ||||
|
| D4: |
| Binning Mode |
|
|
|
|
| 0: OFF (Normal) | 1: ON (Binning) | |||||
|
| D3 to D0: | No Function |
|
|
|
|
| Always set as “1001” |
| ||||||
|
| Note 1: The trigger polarity is automatically set to positive when using the software trigger; the trigger polarity | ||||||||||||||
|
| cannot be changed. |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| ||||||||||||
|
| [Camera function mode 2] Initial data: MOD2[7..0] = 0FH |
|
| ||||||||||||
11H: |
| Sets the camera function mode. |
|
|
|
|
|
|
|
| ||||||
MOD2[7..0] |
| D[7..0] |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| D7 | D6 | D5 | D4 |
| D3 |
| D2 |
| D1 |
| D0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| D7 to D5: | No Function |
|
|
| Always set as “000” |
|
| |||||||
|
| D4: |
| Smear Half Reduction | 0: OFF | 1: ON |
| |||||||||
|
| D3: |
| Operational Mode |
| 0: Trigger Mode | 1: Continuous Mode | |||||||||
|
| D2 to D0: | No Function |
|
|
| Always set as “111” |
|
| |||||||
|
| Note 1: The function mode is enabled whenever the “Continuous/Trigger mode | ||||||||||||||
|
| Note 2: While the camera is in Trigger Mode, the video will not output without the trigger signal input. | ||||||||||||||
|
|
|
|
| ||||||||||||
|
| [Camera function mode 3] Initial data: MOD3[7..0] = 00H |
|
| ||||||||||||
12H: |
| Sets the camera function mode. |
|
|
|
|
|
|
|
| ||||||
MOD3[7..0] |
| D[7..0] |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| D7 | D6 | D5 | D4 |
| D3 |
| D2 |
| D1 |
| D0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| D7 to D6: | No Function |
|
|
| Always set as “00” |
|
| |||||||
|
| D5: |
| Trigger Signal Type |
| 0: Software Trigger | 1: Hardware Trigger | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (from No.5 pin of | |
|
| D4 to D3: | Exposure Start Mode |
| 00: Normal | 10 to 11: H Reset | ||||||||||
|
|
|
|
|
|
|
|
|
| 01: No Function (Prohibited setting. Do not set these values) | ||||||
|
| D2 to D0: | No Function |
|
|
| Always set as “000” |
|
| |||||||
|
| Note 1: The trigger polarity is automatically set to positive when using the software trigger; the trigger polarity | ||||||||||||||
|
| cannot be changed. |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 25/38 | |