Command No.

 

 

 

 

 

 

 

 

 

 

Command Description

 

 

 

 

[Active time (us) for the strobe signal]

 

 

 

 

 

 

 

90H:

 

Initial data: STROBEON _I[23..0] =10, STROBEDELAY _F[7..0] = 0, data range: 0 to 2,000,000

STROBEON_I[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

91H:

 

Active time for the strobe signal = (STROBEON _I[23..0]). (STROBEON _F[7..0]) useconds

STROBEON_I[15..8]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

92H:

Active time for the strobe signal is set as below.

 

 

 

 

 

STROBEON_I[23..16]

 

0: No strobe signal output

 

 

 

 

 

 

 

 

 

 

93H:

 

1 to 9: 10 us

 

 

 

 

 

 

 

 

 

 

 

 

STROBEON_F[7..0]

 

Greater than 9: set value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Output signal selection for the power-I/O connector] Initial data: OUTSEL[7..0] = 20H

F0H:

 

Sets the output signal from the power/IO connector.

 

 

 

OUTSEL

 

D[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

D6

D5

 

D4

 

D3

 

D2

D1

 

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7 to D4:

Output signal for 3pin of the power/IO connector

 

 

 

 

 

 

 

 

 

 

 

 

0: FrameTriggerWait signal

1: UserOutput signal

 

 

 

 

 

 

 

 

 

2: ExposureActive signal

3: TriggerAuxiliary signal

 

 

 

 

 

 

 

 

 

4: TriggerInternal signal (after mask and delay process)

 

 

 

 

 

 

 

 

 

5: SensorReadOut signal

 

 

 

 

 

 

 

 

 

 

 

 

6 to F: No Function (Prohibited setting. Do not set these values)

 

 

D3 to D0:

Output signal for 2pin of the power/IO connector

 

 

 

 

 

 

 

 

 

 

 

 

0: FrameTriggerWait signal

1: UserOutput signal

 

 

 

 

 

 

 

 

 

2: ExposureActive signal

3: TriggerAuxiliary signal

 

 

 

 

 

 

 

 

 

4: TriggerInternal signal (after mask and delay process)

 

 

 

 

 

 

 

 

 

5: SensorReadOut signal

 

 

 

 

 

 

 

 

 

 

 

 

6 to F: No Function (Prohibited setting. Do not set these values)

 

 

Note: When “UserOutput signal” is selected, set the status of the signal with “UserOutput signal for the

 

 

power/IO

connector (TEST2-D3,4)”.

 

 

 

 

 

 

 

 

 

 

 

[UserOutput signal for the power-I/O connector] Initial data: TEST2[7..0] = 00H

 

F1H: TEST2[7..0]

 

Sets the status of the UserOutput signal.

 

 

 

 

 

 

 

 

 

D[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

D6

D5

 

D4

 

D3

 

D2

D1

 

D0

 

 

 

 

 

 

D7 to D5:

No function

 

 

 

 

 

 

 

 

Always set as “000”

 

 

D4:

 

UserOutput signal for 3pin of the power/IO connector

0: Low

1: High

 

 

D3:

 

UswerOuput signal for 2pin of the power/IO connector

0: Low

1: High

 

 

D2 to D0:

No function

 

 

 

 

 

 

 

 

Always set as “000”

 

 

Note: The UserOutput signal is enabled whenever “UserOutput signal” is selected at the “Output signal

 

 

selection (OUTSEL)”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FV-G200B1

30/38

User’s Guide Rev. 1.02

 

Image 30
Contents GigE Vision VGA Monochrome CCD Camera FV-G200B1 FV-G200B1 User’s Guide RevTable of Contents Connector Specifications RJ45 ConnectorDC Iris Lens Connector Power-I/O ConnectorFV-G200B1 User’s Guide Rev Equivalent Circuit for the Input Pin of the I/O Connector Or equivalent connectorHorizontal Timing Vertical Timing Full Scanning2 1/2 Partial Scanning 3 1/4 Partial ScanningAOI Area of Interest Fval Lval SUBPixel Transferring Image Normal Mode Pulse Width Trigger ModeTiming Trigger signal Exposure Timing with the Positive Polarity Trigger SignalInput Trigger signal Trigger signal With Photocoupler delayEdge Preset Trigger Mode 14/38 15/38 16/38 Reset mode Communication Settings Communication MethodCommunication Format Name Descriptions 【Example Code】Reading the data from the command 00H Camera Control Command Camera Command List Device Code22/38 23/38 24/38 Descriptions of the Camera Control Commands Device code Underline settings are the factory default settings26/38 27/38 28/38 29/38 30/38 Descriptions of the Camera Commands Device code AGC32/38 33/38 34/38 GenICam Command / Camera Command Reference Table GenICam command Device Command Function2EH 37/38 38/38