Control terminals
| H |
|
|
|
| S |
|
|
| WARNING | DC13.8V | ||||||
|
| GND |
|
| GND |
|
|
| GND |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 23 4 5 67
5VIDEO OUT terminal (BNC plug)
This terminal is used to connect the camera to a component such as a monitor or camera control unit.
6RESET button
Press the RESET button if an abnormality occurs with the camera. Settings are not changed when the camera is reset in this way.
7Warning indicator
•The warning indicator lights when the camera power is turned on.
•It flashes when there is a hard disk error or if there is a problem with the backup battery.
| Terminal | Signal |
| Input/output voltage |
1 | H | Alarm switch input signal | 2.5 | V or higher when alarm switch off/ |
|
|
| 0.4 | V or lower when alarm switch on |
2 | GND | Alarm switch and suspicion switch ground | 0 V |
|
|
|
|
|
|
3 | S (SUSPICION) | Suspicion switch input signal | 2.5 | V or higher when suspicion switch off/ |
|
|
| 0.4 | V or lower when suspicion switch on |
4 | GND | Warning ground | 0 V |
|
|
|
|
|
|
5 | WARNING | Warning signal output | 3.3 | V or higher when warning generated |
|
|
|
|
|
6 | GND | Power supply ground | 0 V |
|
|
|
|
| |
7 | DC 13.8 V | Power supply input | 13.8 V DC |
8 | English |