Sony DXC-D30WS Fitting the Lens, Fitting optional filters, If using a lens with a 6-pin connector

Page 24

1-20

Fitting the Lens

In the case of the DXC-D30F/D30PF/D30K/D30PK model, the lens is already fitted. In other cases, use the following procedure to fit the lens.

1 Remove the retaining rubber which prevents the lens mount from coming loose, then raise the lens fixing lever, and remove the lens mount cap.

Retaining rubber

4 Using the triangular mark as a guide, push the lens connector into the LENS connector on the camera head, until it clicks into place. Fasten the cable with the clamps.

Chapter 2

 

Fitting and

2 With the lens fixing lever

Connections

 

 

turned fully counterclockwise,

 

push in the lens, aligning the

 

projection on the lens with the

 

cutout on the camera.

3 Supporting the lens, turn the lens fixing lever fully clockwise. Replace the retaining rubber on the lens mount.

Lens mount cap

Align and push in.

Lens fixing lever

If using a lens with a 6-pin connector

This camera head has a 12-pin LENS connector. If the

 

lens cable has a 6-pin connector, fit an adaptor cable:

 

LO-612 (manufactured by Canon) or ECF-124

 

(manufactured by Fujinon) or equivalent.

LENS connector

Triangular mark

Fitting optional filters

Loosen the lens hood fixing screw to remove the lens hood, then attach the filter.

Remove lens hood

Lens hood fixing screw

Filter (optional)

Chapter 2 Fitting and Connections

DXC-

 

 

D30WS/P(E)/V1

26

Chapter 2 Fitting and Connections

 

Chapter 2 Fitting and Connections

27

Image 24 Contents
DXC-D30WS DXC-D30WSP Varning Manual Structure Introducing this manual Related manualsTable of Contents Digital Video Camera Operating instructionsTable of Contents Overview Advanced Menu Settings FeaturesAbout This Manual Battery Pack Operating Times Advanced Menu Settings Video Output and Viewfinder PictureItemSettings Specifications Supplied accessoriesRelated Products DXC-D30WSL/D30WSPL Camera HeadSpecifications Measuring Horizontal ResolutionHorizontal resolution in 169 mode Horizontal resolution in 43 modeChart of Optional Components and Accessories DXCUsing the Camcorder Grip Using Battery Packs Camera Adaptor Power SupplyCamera Head VCL-916BYA Zoom Lens DXF-701/701CE Viewfinder Table of Contents Product Configurations Camera adaptorFeatures Location and Function of Parts Camera HeadLocation and Function of Parts Front view Left and upper viewVCL-916BYA Zoom Lens DXF-701/701CE Viewfinder Location and Function of Parts Using the Camcorder Grip Fitting a VTRAttaching a camcorder grip to the DSR-1/1P To remove the VTRFitting a VTR Attaching a camcorder grip to the PVV-3/3PIf using a lens with a 6-pin connector Fitting the LensFitting optional filters Using Accessories Using the ViewfinderUsing an Optional Microphone Using Accessories Adjusting the Shoulder Pad PositionFitting to a Tripod Fitting an optional microphoneUsing Accessories Using the Carrying Case Connecting a Portable VTRConnections Connecting a Number of Cameras Using a Camera Control Unit ConnectionsConnected VTR VTRPower Supply Using Battery PacksBattery pack operating times Battery low indicationsBasic Procedure for Shooting Power Supply Camera Adaptor Power SupplyCamera with a separate power supply Filter setting Lighting conditionsBasic Procedure for Shooting Using the ClipLink FunctionShooting with the DSR-1/1P Reviewing the recordingUsing the Edit Search Function While Back Space Editing Setting Mark IN/OUT points as you shootSetting cue points as you shoot Shooting with the DSR-1/1PUsing the Freeze Mix Function Viewfinder Screen IndicationsChanging the Viewfinder Display Viewfinder Normal Indications Viewfinder Screen IndicationsViewfinder Normal Indications Contents and Settings of Each Viewfinder Basic MenuStatus Indications Basic Menu OperationsSetting the recording time in seconds Setting the recording time in minutesViewfinder Basic Menu Basic menu pages 8 Entering the titleDSR-1/1P To record a titleViewfinder Advanced Menu Advanced Menu OperationsTo change To return to the normal indicationsViewfinder Advanced Menu EZ mode settings Advanced menu pages 9 toAdvanced menu pages 13 To set the camera ID38Setup Files Calling up a Setup FileUsing the DSR-1/1P To call up files recorded onto a tape whenSetup Files Changing File Settings Saving File SettingsTo save setup files to a tape when using the DSR-1/1P Using SetupNavi and SetupLog with the DSR-1/1P Setup FilesSetting up the camera Using Data Recorded on Tape Using SetupNavi and SetupLog with the DSR-1/1P Recording the Menu Settings onto a TapeViewing SetupLog Data To abort the data recording while in progressWhite Balance Adjustment Saving an Appropriate White Balance Value in MemoryWhite Balance Adjustment Light Sources and Color TemperatureUsing the ATW Auto Tracing White Balance Function Using the Preset White Balance Settings44Black Balance Adjustment Shutter Settings Setting the shutter speed, CLS and EVS functionShutter speeds CLS Clear Scan functionSetting the Clock and Timestamping Recordings Shutter SettingsHow to set the date and time When shooting is finishedViewfinder Screen Adjustments 46Setting the Clock and Timestamping RecordingsAdjusting the Lens Flange Focal Length AdjustmentIris Adjustments Using the zebra pattern in manual adjustment modeSettings for Special Cases 48Adjusting the Lens MacrophotographyEnding close-up shooting Reducing the size of the imageSettings for Special Cases Adjusting Color in the Specified AreaCharacteristics of CCD Sensors Important Notes on OperationDXC-D30/D30P Camera Head VCL-916BYA Zoom LensDesign and specifications are subject to change DXF-701/701CE ViewfinderHood VCL-915BYA/916BY/1012BY Zoom Lens52Chart of Optional Components and Accessories VHS VTRBoard Layout Removal of CabinetRemoval of Side Plate Replacement of Main Parts Replacement of CCD UnitDisassembly AssemblyCN2 Connectors and Cables Connector Input/Output SignalsPin Signal Specification CAMERA/CA 76P, Male Remote 10P, Female VF 20P, Female HOW to Handle of AT-125 Board Connection ConnectorHow to Attach of the Extension Board EX-591 Replacement Way of ROMIC102DC-DC Converter Voltage External View Check Point Voltage ValueService Mode Operation Service modeMenu screen ConnectionReset object item and standard set value for setting Table Standard set value1 Reset 3 Flare Adjustment4 Pre Knee Setting 2 Standing Correction5 Component Level Adjustment 6 CLP Level Adjustment7 Chroma/VF Adjustment 8 SC adjustment9 Various kinds items setting 10 Test Mode11 Head Block No. information 12 RG, SUB communication13 Various items setting 14 Title Color setting15 Various items setting 16 Knee setting 3 not in used17 Various setting 18 Selfdiagnosis19 Selfdiagnosis 20 Selfdiagnosis21 Selfdiagnosis RC-PMPDRC-CY RC-CCRDSP COM Memory22 Present unit condition indication 23 TG ROM OperationGrayscale chart PreparationEquipment Required Connection Pattern box PTB-500Switch Setting Before Adjustment Adjustment Item Before Adjustment Color Bar Signal ConfirmationSensitivity Measurement Confirmation Camera Adjustment Sub-Carrier Frequency AdjustmentINT SC-H Phase Adjustment 3. Y/R-Y/B-Y CLP Level Adjustment4. Y/SYNC/R-Y/B-Y Level Adjustment Carrier Balance AdjustmentAdjusting point LVL UP LVLChroma VBS Level Adjustment VBS Level Adjustment→ SET UP on MAT Dest Smpte To be extended ES-22 board PreparationYC Level Adjustment Chroma YC Level AdjustmentSpecification for Ntsc VF SYNC/BLKG Level Adjustment Specification a = 165 ±5 mVVF Sync → VF Blkg → CAM/DCC+Pedestal Adjustment Shading AdjustmentTest point Spec Mode VA-185 board → R Shad G Shad B ShadFlare Adjustment MIC LEVEL/MIC Level IND AdjustmentAdjusting point Lens iris →CAM/DCC+Character Position Adjustment Title AdjustmentAdjusting point 1CV3/MB-785 board Specification Adjusting point 1CV1/MB-785 board SpecificationPage Sony Corporation