Hasselblad 10026 service manual Adjustment of the release sequence

Page 24

5:6

Camera body 503CW

Adjustment

Adjustment of the release sequence

Make sure the winding knob V-2206 and the bayonet plate tool 904644 are installed.

Release the camera and keep it released by holding the release bar and push rod back.

Move the release bar and push rod to the front slowly and observe the closing sequence.

Fig. 41.

1.Key releases to fully released position.

2.Auxiliary shutter closes. Note that the winding knob is blocked all the time until the auxiliary shutter closes.

V-2206

904644

3.The stop lever disengage giving clearance for the winding knob.

The auxiliary shutter closing position can be adjusted by bending the rear of the release arm (13357) which bears on pin ”A” as shown.

Use the tool V-2203.

Check for free play between the release bar and signal arm when the camera is fully released.

Fig. 42.

Fig. 41

13357

"A"

Free play

when fully released

Fig. 42

Note! The final sequence check is done when the chassis is mounted in to the shell by using the exposure gauge V-2354. (See page 5:11).

Check that the auxiliary shutter does not close spontaneously when the camera is pre-released. Carry out a number of operations of the release arm (13357). If the auxiliary shutters do close using this test, adjust the tongue on lever (22769) which stops the release arm against the signal arm.

Check the lever does not jam between the release arm and the signal arm when the camera is released.

Test by operating the shutter and letting the release bar return slowly. Check that the lever has a small amount of play during this movement.

Fig. 43.

13357

Free play

22769

Adjust here

Fig. 43

Revision 0

October 1996

Image 24
Contents Victor Hasselblad AB Göteborg SwedenContents list Camera body 503CW Updated pages 503CXi Signal arm shortened 501C and 503CXiFitted with wrong spacers 503C/M and 503CX Flash metering circuit redesigned 503CX04/01 New CD-ROM Version General description Camera typeRelease sequence Tool No Description Tools Used forTool No Description Used for Camera shell Circuit board 22575 *22882 Front bayonet plateRear plate 30300 including auxiliary shutter Focusing screen frame Right hand wallMechanism plate Gear housing Reassembly 816802 Fitting the mechanism plate to the right hand wall 821631 13108 814827 13355 13280 13362 Rear plate Perform the necessary adjustment as described in section Front plateIntermediate gear Adjustment Adjustment of the front key’s angular position Focal lengthAngle 15-16 o with the bayonet plate tool 904644 pushed Adjustment of the release mechanism 15 mm Adjustment of the release sequence Fitting the damping ring Adjustment Fitting the camera body into the shell Fitting the Circuit board 22575 *22882Final checks 510 Camera body 503CW 511 Camera body 503CW 512 Camera body 503CW 513 Camera body 503CW Front plate reassembly Front gearFront bayonet plate Exchanging the mirror Exchanging the auxiliary shutterShim washers Revision May Pos Pcs Spare Description Remark May Camera body 503CW Camera body 503CW Camera body 503CW September Camera body 503CW Camera body 503CW Camera body 503CW Camera body 503CW Camera body 503CW October May Camera body 503CW Camera body 503CW 151 Spare parts not listed are the same as for 503CW 152 152 153 153 154 154 155 Coupling Crank support 161 Pos Pcs No Spare Part No Description Remark 162 Pos Pcs Spare Description Remark 163 163 171 171 172 172 173 173 174 174 175 175 181 181 182 182 183 183 184 184 185 January 191 October 192 192 193 193