6:3
Camera body 503CW | Auxillary shutter & Mirror |
Exchanging the mirror (22775)
Release the camera.
Inside the mirror box, remove the clip "A" and disengage the arm (22781) from the mirror frame. Remove the washer (810649) located behind the arm and the frame.
Remove the sleeve (22800). Fig. 58.
Carefully wind on until the mirror is visible in the front plate
Remove the mirror (22775) and the light trap (22776) which is placed underneath the mirror.
Fig. 59.
810649 |
22781 |
22800 |
"A" |
Fig. 58
After a new mirror has been mounted in to the frame check for ease of operation.
Mount a new sleeve (22800) with the counter sunk side facing out.
Note! If the spring (22804) has to be replaced, the new one should be glued in the mirror frame with
Loctite 480.
Fig. 59
Exchanging the auxiliary shutter
Note! For convenience use the aux. shutter jig
Remove the two pins (811108), spring retainer, spring (816805) and lever 13185.
Remove the safety lacquer and loosen the locking screws (825661). Remove the hubs (840514).
The upper shutter flap and mirror frame can now be removed. Ensure that all adjustment washers on the shaft are retained. The lower shutter flap is dismantled in a similar manner. The light trap 13125 is held in place by two screws (821203).
Fig. 60.
825661 |
840514 |
816805 |
13185 |
13125 |
811108 |
Fig. 60
Revision 0 | October 1996 |