Hasselblad 10026 service manual Final checks

Page 27

5:9

Camera body 503CW

Adjustment

Adjust the lower rear plate/shell alignment and tighten the two rear screws (829755)and seal with loctite.

Fit and tighten the two front screws (820781).

Check the upper edge alignment of rear plate and shell. Adjust, if necessary, the two screws (825760) which are accessible behind the leathers mounted on the shell.

Note! The rear edge of the shell must not protrude over the rear plate at any point.

Fit the tripod foot (30763) with the remaining six screws (829755). Screws sealed with loctite.

Fit the washer (22799) and coupling (22767). Secure with screw (830060).

Fit the ISO selector knob and secure it with the screw (822701). Fit the shim (22473) and leather (13374). Do not damage the sliding contacts.

Fit the two screws (823335) behind the leather securing the chassis connector.

Operate the pre-release on the camera body and fit the front gear cover (22876) and a new side cover (22813), if it has been removed.

The side cover is held in position by double sided tape and the upper part of it held by the screen frame. Mount the spring (30775) in the mirror box using the small screwdriver (Tool No. 905020).

Mount the winding crank.

Operate the camera body and make sure it is working properly.

825760 are accessible

behind the leathers

ISO knob

22767

823335

22799

820781

830060

829755

Fig. 50

Final checks

Place the camera in the focusing gauge V-2229. Zero the dial indicator by placing it on surface ”A”. Mount the front plate ”B” into the front bayonet of the camera. Place the ruler with indicator clock onto the gauge and move the indicator around the periphery of the front plate and check that the length is within the tolerance ± 0.03 mm. If to long, the camera can be shortened by carefully striking the plate with a plastic hammer. (Focal length is 71.40 mm).

Note! If the camera is to short it must be taken out from the shell again for an adjustment.

"B"

"A"

Fig. 51

Revision 1

January 2001

Image 27
Contents Göteborg Sweden Victor Hasselblad ABContents list Camera body 503CW Flash metering circuit redesigned 503CX Updated pages 503CXiSignal arm shortened 501C and 503CXi Fitted with wrong spacers 503C/M and 503CX04/01 New CD-ROM Version Camera type General descriptionRelease sequence Tools Used for Tool No DescriptionTool No Description Used for Camera shell Circuit board 22575 *22882 Front bayonet plateRear plate 30300 including auxiliary shutter Focusing screen frame Right hand wallMechanism plate Gear housing Reassembly 816802 Fitting the mechanism plate to the right hand wall 821631 13108 814827 13355 13280 13362 Rear plate Perform the necessary adjustment as described in section Front plateIntermediate gear Adjustment Focal length Adjustment of the front key’s angular positionAngle 15-16 o with the bayonet plate tool 904644 pushed Adjustment of the release mechanism 15 mm Adjustment of the release sequence Fitting the damping ring Fitting the Circuit board 22575 *22882 Adjustment Fitting the camera body into the shellFinal checks 510 Camera body 503CW 511 Camera body 503CW 512 Camera body 503CW 513 Camera body 503CW Front gear Front plate reassemblyFront bayonet plate Exchanging the auxiliary shutter Exchanging the mirrorShim washers Revision May Pos Pcs Spare Description Remark May Camera body 503CW Camera body 503CW Camera body 503CW September Camera body 503CW Camera body 503CW Camera body 503CW Camera body 503CW Camera body 503CW October May Camera body 503CW Camera body 503CW 151 Spare parts not listed are the same as for 503CW 152 152 153 153 154 154 155 Coupling Crank support 161 Pos Pcs No Spare Part No Description Remark 162 Pos Pcs Spare Description Remark 163 163 171 171 172 172 173 173 174 174 175 175 181 181 182 182 183 183 184 184 185 January 191 October 192 192 193 193