Hasselblad 10026 service manual Fitting the Circuit board 22575 *22882

Page 26

5:8

Camera body 503CW

Fitting the Circuit board (22575) *22882

CAUTION! When handling the circuit board a grounded bench mat and a wrist strap must be used to prevent ESD damage.

Put the insulating plate (22746) in position and place the circuit board on top of it. Secure the board by first fitting the two screws (820015) followed by the attachment (22453).

*Note! The circuit board (22882) is fixed to the wall by an insulating double-sided tape, screws and attachment.

Put the photo diode in position on the inside of the bottom part of the left hand wall and secure from the outside with two screws (820325).

Fit the cable holder (12453) and securing the cables with screw (820011).

Fig. 47.

Adjustment

Fig. 47

Fitting the camera body into the shell

Install the lens release button (13139), release button (22759), buffer (22367), and the distance washers (810620) into the shell.

Put the teflon cone (103373) in position on the camera body.

The camera body can be fitted into the shell. Fig. 48.

Note! That the S-arm (21167) has to be fitted using a spring hook to ensure that the pre-lease button (22385) is positioned beneath the S-lever.

Fig. 49.

* From camera serial No. 19ER18271

Revision 3

Fig. 48

Fig. 49

May 2000

Image 26
Contents Victor Hasselblad AB Göteborg SwedenContents list Camera body 503CW Fitted with wrong spacers 503C/M and 503CX Updated pages 503CXiSignal arm shortened 501C and 503CXi Flash metering circuit redesigned 503CX04/01 New CD-ROM Version General description Camera typeRelease sequence Tool No Description Tools Used forTool No Description Used for Camera shell Rear plate 30300 including auxiliary shutter Circuit board 22575 *22882Front bayonet plate Mechanism plate Focusing screen frameRight hand wall Gear housing Reassembly 816802 Fitting the mechanism plate to the right hand wall 821631 13108 814827 13355 13280 13362 Rear plate Intermediate gear Perform the necessary adjustment as described in sectionFront plate Adjustment Adjustment of the front key’s angular position Focal lengthAngle 15-16 o with the bayonet plate tool 904644 pushed Adjustment of the release mechanism 15 mm Adjustment of the release sequence Fitting the damping ring Adjustment Fitting the camera body into the shell Fitting the Circuit board 22575 *22882Final checks 510 Camera body 503CW 511 Camera body 503CW 512 Camera body 503CW 513 Camera body 503CW Front plate reassembly Front gearFront bayonet plate Exchanging the mirror Exchanging the auxiliary shutterShim washers Revision May Pos Pcs Spare Description Remark May Camera body 503CW Camera body 503CW Camera body 503CW September Camera body 503CW Camera body 503CW Camera body 503CW Camera body 503CW Camera body 503CW October May Camera body 503CW Camera body 503CW 151 Spare parts not listed are the same as for 503CW 152 152 153 153 154 154 155 Coupling Crank support 161 Pos Pcs No Spare Part No Description Remark 162 Pos Pcs Spare Description Remark 163 163 171 171 172 172 173 173 174 174 175 175 181 181 182 182 183 183 184 184 185 January 191 October 192 192 193 193